Service time: Monday to Friday 9:00-18:00
3RA6120-0EB30 - 3RA6120-0EB30 SIEMENS SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 8...32 A IP20 Conne..
In Stock Hot Product

3RA6120-0EB30

3RA6120-0EB30 SIEMENS SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 8...32 A IP20 Conne..

$0.00USD
3081 in stock
Key Specifications
:Value
EAN:4011209778436
UPC:754554962689
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209778436
UPC754554962689
ETIM4
IDEA4
depth165 mm
width45 mm
UNSPSC14
eClass6
height170 mm
B10 value
Group CodeR711
trip classCLASS 10 and 20 adjustable
Price Group42F
Metal FactorLCO-----
● at 250 V0.27 A
Holding power
Product Group5341
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
Product family3RA61 direct-on-line starters
last modified:08/25/2020
number of LEDs2
Net Weight (kg)1,385 Kg
type of voltageAC/DC
● rated value690 V
Depth (EF000049)165.0
Width (EF000008)45.0
Country of originGermany
Height (EF000040)170.0
Marine / Shippingother
● 1 rated value50 Hz
● 2 rated value60 Hz
● at AC maximum3.5 W
● at DC maximum3.1 W
● mounting typescrew and snap-on mounting
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
Type of assignmentcontinous operation according to IEC 60947-6-2
failure rate [FIT]
insulation voltage
product brand nameSIRIUS
Operating frequency
Packaging Dimension181,50 x 228,50 x 59,50
Product DescriptionSIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 8...32 A IP20 Connection main circuit: plug-in, without terminals Connection auxiliary circuit: plug-in, without terminals
degree of pollution3
product designationcompact starter
protection class IPIP20
With fuse (EF006693)false
● shock resistancea=60 m/s2 (6g) with 10 ms per 3 shocks in all axes
design of the productdirect starter
● at DC rated value24 V
● mounting positionany
Product Lifecycle (PLM)PM300:Active Product
Control supply voltage 1
General Product ApprovalEMC
Release class (EF006668)Adjustable
product type designation3RA61
— at 400 V rated value29 A
— at 500 V rated value17.6 A
— at 690 V rated value12.8 A
● at 400 V rated value15 kW
● at 480 V rated value32 A
● at 50 Hz rated value24 V
● at 500 V rated value11 kW
● at 60 Hz rated value24 V
● at 690 V rated value11 kW
● vibration resistancef= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
No-load switching frequency3 600 1/h
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
● operating power at AC-3
Package size unit of measureMM
— at 200/208 V rated value7.5 hp
— at 220/230 V rated value10 hp
— at 460/480 V rated value20 hp
● Operating power at AC-43
● for main current circuitplug-in without terminals
● for three-phase AC motor
type of electrical connection
Control supply voltage 1 at AC
Product Dimensions (W x L x H)Not available
● Operating current at AC-43
Type of motor starter (EF009598)Direct online starter (DOL)
control supply voltage frequency
degree of protection NEMA ratingother
proportion of dangerous failures
Rail mounting possible (EF003972)-
● Mounting position recommendedvertical, on horizontal standard mounting rail
External reset possible (EF003426)-
product function bus communicationNo
relative humidity during operation10 ... 90 %
yielded mechanical performance [hp]
● at DC-13 at 6 A at 24 V typical30 000
Degree of protection (IP) (EF005474)IP20
surge voltage resistance rated value6 000 V
● at AC-15 at 6 A at 230 V typical200 000
Article Number (Market Facing Number)3RA6120-0EB30
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)32
Voltage type for actuating (EF008242)AC/DC
With short-circuit release (EF006691)true
reference code acc. to DIN EN 81346-2Q
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● ambient temperature during storage-55 ... +80 °C
● between main and auxiliary circuit400 V
● design of short-circuit protectionelectromagnetic
● product extension auxiliary switchYes
number of poles for main current circuit3
● ambient temperature during operation-20 ... +60 °C
● ambient temperature during transport-55 ... +80 °C
Formula for making capacity limit current12 x Ie
Supply voltage required Auxiliary voltageNo
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
● between control and auxiliary circuit300 V
● with low demand rate acc. to SN 3192040 %
Supporting protocol for SUCONET (EF003060)-
● Protocol is supported IO-Link protocolNo
● at AC-41 acc. to IEC 60947-6-2 maximum750 1/h
● at AC-43 acc. to IEC 60947-6-2 maximum250 1/h
● with high demand rate acc. to SN 319202 000 000
Mechanical power output for 4-pole AC motor
Overload release current setting (EF002336)['8', '32']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
● between auxiliary and auxiliary circuit250 V
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
electrostatic discharge acc. to IEC 61000-4-28 kV
● for auxiliary and control current circuitplug-in without terminals
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
maximum permissible voltage for safe isolation
Formula for interruption capacity limit current10 x Ie
Rated operation power at AC-3, 400 V (EF001364)15.0
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
● protocol is supported AS-Interface protocolNo
Rated control supply voltage Us at DC (EF003980)['-', '24']
full-load current (FLA) for three-phase AC motor
operating current of auxiliary contacts at DC-13
● Operating current at AC at 400 V rated value32 A
● number of NC contacts for auxiliary contacts1
● number of NO contacts for auxiliary contacts1
Rated operation current at AC-3, 400 V (EF009602)-
● operating voltage at AC-3 rated value maximum690 V
Supporting protocol for INTERBUS-Safety (EF006662)-
Conducted HF-interference emissions acc. to CISPR11150 kHz ... 30 MHz Class A
Supporting protocol for DeviceNet Safety (EF007520)-
Field-bound HF-interference emission acc. to CISPR1130 ... 1000 MHz Class A
Supporting protocol for other bus systems (EF003062)-
contact rating of auxiliary contacts according to ULcontacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300
field-bound parasitic coupling acc. to IEC 61000-4-310 V/m
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '24']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '24']
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
Product function Control circuit interface with IO linkNo
Coordination class according to IEC 60947-4-3 (EF012390)continous operation according to IEC 60947-6-2
Operating current of auxiliary contacts at AC-12 maximum10 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Other
● Product function removable terminal for main circuitYes
● installation altitude at height above sea level maximum2 000 m
Electrical endurance (switching cycles) of auxiliary contacts
● conducted interference due to burst acc. to IEC 61000-4-44 kV main contacts, 2 kV auxiliary contacts
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)1
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
● Product function Control circuit interface to parallel wiringYes
Number of auxiliary contacts as normally closed contact (EF001377)1
T1 value for proof test interval or service life acc. to IEC 6150820 y
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
● Operational short-circuit current breaking capacity (Ics) at 400 V53 kA
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● product function removable terminal for auxiliary and control circuitYes
adjustable pick-up value current of the current-dependent overload release8 ... 32 A
● mechanical service life (switching cycles) of the main contacts typical10 000 000
● mechanical service life (switching cycles) of auxiliary contacts typical10 000 000
● Conducted interference due to conductor-earth surge acc. to IEC 61000-4-54 kV main contacts, 2 kV auxiliary contacts
● power loss [W] for rated value of the current at AC in hot operating state5.4 W
power loss [W] for rated value of the current without load current share typical3.5 W
● Mechanical service life (switching cycles) of the signaling contacts typical10 000 000
● conducted interference due to high-frequency radiation acc. to IEC 61000-4-60.15-80Mhz at 10V
● Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-52 kV main contacts, 1 kV auxiliary contacts
● operational short-circuit current breaking capacity (Ics) at 500 V rated value1 kA
● operational short-circuit current breaking capacity (Ics) at 690 V rated value1 kA
Type of electrical connection for auxiliary- and control current circuit (EF006979)Other
● power loss [W] for rated value of the current at AC in hot operating state per pole1.8 W
● Number of NO contacts of instantaneous short-circuit trip unit for signaling contact1
● Number of CO contacts of the current-dependent overload release for signaling contact1
● design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
● Design of the fuse link for short-circuit protection of the signaling switch of the overload release required4A gL/gG/400V
● Design of the fuse link for short-circuit protection of the signaling switch of the short-circuit release required6A gL/gG/400V
General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top