| Parameter | Value |
|---|---|
| EAN | 4011209974180 |
| UPC | 804766060830 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 74 mm |
| width | 45 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 38 mm |
| ● at DC | 90 ... 240 V |
| ● solid | 0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²) |
| Group Code | R711 |
| — upwards | 0 mm |
| Confirmation | |
| Metal Factor | None |
| — forwards | 0 mm |
| ● ON-delay | No |
| ● at 50 Hz | 90 ... 240 V |
| ● at 60 Hz | 90 ... 240 V |
| ● stranded | 20 ... 14 |
| Date5/14/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 5347 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| recovery time | 50 ms |
| — backwards | 0 mm |
| — downwards | 0 mm |
| ● OFF delay | Yes |
| Commodity Code | 85364900 |
| Product family | 3RA28 function modules |
| last modified: | 12/19/2020 |
| Net Weight (kg) | 0,096 Kg |
| adjustable time | 0.05 ... 100 s |
| type of voltage | AC/DC |
| — at the side | 0 mm |
| fastening method | clip-on |
| product function | |
| required spacing | |
| ● non-volatile | No |
| Country of origin | Czech Republic |
| Marine / Shipping | other |
| minimum ON period | 35 ms |
| mounting position | any (like contactor) |
| ● initial value | 0.85 |
| ● pulse delayed | No |
| ● pulse-shaping | No |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| switching function | |
| type of insulation | Basic insulation |
| ● during storage | -40 ... +85 °C |
| ● for live parts | |
| Packaging Dimension | 47,00 x 107,00 x 55,00 |
| Product Description | Electronic timing relay OFF delay With control signal and semiconductor output 90-240 V AC/DC Time range 0.05...100 s Can be snapped on at the front For contactors 3RT2, S2, S3 and 3RH2 S00 contactor relays Screw terminal |
| ambient temperature | |
| degree of pollution | 3 |
| product designation | function module |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +85 °C |
| ● full-scale value | 1.1 |
| number of NO contacts | |
| ● additive ON-delay | No |
| ● delayed switching | 1 |
| conducted interference | |
| power supply influence | ±1 % |
| ● ON-delay/OFF-delay | No |
| ● for grounded parts | |
| ● star-delta circuit | No |
| Product Lifecycle (PLM) | PM300:Active Product |
| Setting time (EF005922) | ['0.05', '100.0'] |
| ● at AWG cables solid | 2x (20 ... 14) |
| General Product Approval | Declaration of Conformity |
| control supply voltage 1 | |
| product type designation | 3RA28 |
| relative repeat accuracy | 1 % |
| ● passing make contact | No |
| ● passing break contact | No |
| Export Control Regulations | AL : N / ECCN : N |
| ● at AWG cables stranded | 2x (20 ... 14) |
| Standard lead time ex-works | 60 Day/Days |
| Surcharge for Raw Materials | None |
| ● OFF delay/instantaneous | No |
| Package size unit of measure | MM |
| Substance Prohibitance (Date) | 10/01/2009 |
| Switching function (EF000189) | - |
| Operating principle (EF004139) | Electronic |
| category according to EN 954-1 | none |
| control supply voltage 1 at AC | |
| design of the surge suppressor | with varistor |
| ● with side-by-side mounting | |
| test voltage for isolation test | 1.5 kV |
| ● pulse delayed/instantaneous | No |
| ● pulse-shaping/instantaneous | No |
| control supply voltage frequency 1 | 50 ... 60 Hz |
| relative humidity during operation | 0 ... 95 % |
| ● ON-delay/instantaneous contact | No |
| connectable conductor cross-section | |
| product function star-delta circuit | No |
| protection class IP of the terminal | IP20 |
| test voltage for surge voltage test | 4 800 V |
| ● additive ON-delay/instantaneous | No |
| surge voltage resistance rated value | 4 kV |
| ● ON-delay/OFF-delay/instantaneous | No |
| Article Number (Market Facing Number) | 3RA2832-1DH10 |
| EMC immunity according to IEC 61812-1 | Environment A (industrial area) |
| ● variably clocked with pulse start | No |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| switching function with control signal | |
| ● star-delta circuit with delay time | No |
| electrical endurance (switching cycles) | |
| product component semi-conductor output | Yes |
| reference code according to IEC 81346-2 | K |
| ● passing break contact/instantaneous | No |
| influence of the surrounding temperature | ±1 % |
| ● variably clocked with interval start | No |
| ● with contactor 3R.2 of frame size S2 | 5 000 000 |
| ● with contactor 3R.2 of frame size S3 | 3 000 000 |
| product extension optional remote control | No |
| product extension required remote control | No |
| ● constant clock cycle with pulse start | No |
| mechanical service life (switching cycles) | |
| design of the control terminal non-floating | Yes |
| ● due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| ● flashing symmetrically with pulse start | No |
| shock resistance according to IEC 60068-2-27 | 15g / 11 ms |
| type of connectable conductor cross-sections | |
| ● constant clock cycle with interval start | No |
| ● finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● flashing asymmetrically with pulse start | No |
| type of voltage of the control supply voltage | AC/DC |
| ● flashing symmetrically with interval start | No |
| ● passing make contact/instantaneous contact | No |
| operating frequency with 3RT2 contactor maximum | 2 500 1/h |
| vibration resistance according to IEC 60068-2-6 | 10 ... 59 Hz: 0.35 mm, 60 ... 150 Hz: 2g |
| ● finely stranded without core end processing | 2x (0.5 ... 1.5 mm²) |
| ● flashing asymmetrically with interval start | No |
| ● retriggerable with deactivated control signal | No |
| electrostatic discharge according to IEC 61000-4-2 | 8 kV |
| mechanical service life (switching cycles) typical | 100 000 000 |
| size of contactor can be combined company-specific | S2, S3 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Number of contacts as change-over contact (EF008257) | - |
| Region Specific PriceGroup / Headquarter Price Group | 41B / 41B |
| ● retrotriggerable with switched-on control signal | No |
| Number of contacts as normally open contact (EF008256) | - |
| relative setting accuracy relating to full-scale value | 15 % |
| AWG number as coded connectable conductor cross section | |
| installation altitude at height above sea level maximum | 2 000 m |
| protection class IP on the front according to IEC 60529 | IP20 |
| Number of contacts as normally closed contact (EF008255) | - |
| switching function of interval relay with control signal | |
| ● flashing symmetrically with pulse start/instantaneous | No |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| ● flashing symmetrically with interval start/instantaneous | No |
| operating range factor control supply voltage rated value at DC | |
| type of electrical connection for auxiliary and control circuit | screw-type terminals |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 10 000 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 |
| product component removable terminal for auxiliary and control circuit | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| ● retrotriggerable with deactivated control signal/instantaneous contact | No |
| ● retrotriggerable with switched-on control signal/instantaneous contact | No |
| insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value | 300 V |
| General Product ApprovalDeclaration of ConformityTest CertificatesConfirmationUK Declaration of ConformityType Test Certificates/Test ReportMarine / ShippingMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide