Key Specifications
:
EAN:4011209789845
UPC:040892574661
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209789845
UPC040892574661
ETIM5
IDEA4
depth74 mm
width45 mm
UNSPSC14
eClass6
height38 mm
● at DC24 ... 240 V
● solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
Group CodeR711
— upwards0 mm
Confirmation
Date5/6/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
— forwards0 mm
● ON-delayYes
● at 50 Hz24 ... 240 V
● at 60 Hz24 ... 240 V
● stranded20 ... 14
Product Group5347
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
recovery time50 ms
— backwards0 mm
— downwards0 mm
● OFF delayNo
Commodity Code85364900
Product family3RA28 function modules
last modified:12/19/2020
Net Weight (kg)0,075 Kg
adjustable time0.05 ... 100 s
type of voltageAC/DC
— at the side0 mm
fastening methodclip-on
product function
required spacing
● non-volatileNo
Country of originCzech Republic
Marine / Shippingother
Test CertificatesMarine / Shipping
mounting positionany (like contactor)
● initial value0.85
● pulse delayedNo
● pulse-shapingNo
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
switching function
type of insulationBasic insulation
● during storage-40 ... +85 °C
● for live parts
Packaging Dimension50,00 x 105,00 x 45,00
Product DescriptionElectronic timing relay ON delay with semiconductor output 24-240 V AC/DC Time range 0.05...100 s can be snapped on at the front for contactors 3RT2 S00/S0 and auxiliary contactor 3RH2 S00 Screw terminal Varistor for attenuation of the contactor coils integrated
ambient temperature
degree of pollution3
product designationfunction module
● during operation-25 ... +60 °C
● during transport-40 ... +85 °C
● full-scale value1.1
number of NO contacts
● additive ON-delayNo
● delayed switching1
conducted interference
power supply influence±1 %
● ON-delay/OFF-delayNo
● for grounded parts
● star-delta circuitNo
Product Lifecycle (PLM)PM300:Active Product
Setting time (EF005922)['0.05', '100.0']
● at AWG cables solid2x (20 ... 14)
General Product ApprovalDeclaration of Conformity
control supply voltage 1
product type designation3RA28
relative repeat accuracy1 %
residual current maximum5 mA
● passing make contactNo
● passing break contactNo
Export Control RegulationsAL : N / ECCN : N
● at AWG cables stranded2x (20 ... 14)
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
● OFF delay/instantaneousNo
Package size unit of measureMM
Substance Prohibitance (Date)10/01/2009
Switching function (EF000189)Operating delayed
Operating principle (EF004139)Electronic
category according to EN 954-1none
control supply voltage 1 at AC
design of the surge suppressorwith varistor
● with side-by-side mounting
test voltage for isolation test1.5 kV
● pulse delayed/instantaneousNo
● pulse-shaping/instantaneousNo
Type Test Certificates/Test Report
control supply voltage frequency 150 ... 60 Hz
relative humidity during operation0 ... 95 %
● ON-delay/instantaneous contactNo
connectable conductor cross-section
product function star-delta circuitNo
protection class IP of the terminalIP20
test voltage for surge voltage test4 800 V
● additive ON-delay/instantaneousNo
surge voltage resistance rated value4 kV
● ON-delay/OFF-delay/instantaneousNo
Article Number (Market Facing Number)3RA2811-1CW10
EMC immunity according to IEC 61812-1Environment A (industrial area)
● variably clocked with pulse startNo
WEEE (2012/19/EU) Take-Back ObligationYes
switching function with control signal
● star-delta circuit with delay timeNo
electrical endurance (switching cycles)
product component semi-conductor outputYes
reference code according to IEC 81346-2K
● passing break contact/instantaneousNo
influence of the surrounding temperature±1 %
● variably clocked with interval startNo
● with contactor 3R.2 of frame size S010 000 000
product extension optional remote controlNo
product extension required remote controlNo
● constant clock cycle with pulse startNo
● with contactor 3R.2 of frame size S0010 000 000
design of the control terminal non-floatingNo
● due to burst according to IEC 61000-4-42 kV network connection / 1 kV control connection
● flashing symmetrically with pulse startNo
shock resistance according to IEC 60068-2-2715g / 11 ms
type of connectable conductor cross-sections
● constant clock cycle with interval startNo
● finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● flashing asymmetrically with pulse startNo
type of voltage of the control supply voltageAC/DC
● flashing symmetrically with interval startNo
● passing make contact/instantaneous contactNo
operating frequency with 3RT2 contactor maximum2 500 1/h
vibration resistance according to IEC 60068-2-610 ... 59 Hz: 0.35 mm, 60 ... 150 Hz: 2g
● finely stranded without core end processing0.25 ... 1.5 mm²
● flashing asymmetrically with interval startNo
● retriggerable with deactivated control signalNo
electrostatic discharge according to IEC 61000-4-28 kV
mechanical service life (switching cycles) typical100 000 000
size of contactor can be combined company-specificS00, S0
field-based interference according to IEC 61000-4-310 V/m
Number of contacts as change-over contact (EF008257)-
Region Specific PriceGroup / Headquarter Price Group41B / 41B
● retrotriggerable with switched-on control signalNo
Number of contacts as normally open contact (EF008256)-
relative setting accuracy relating to full-scale value15 %
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Number of contacts as normally closed contact (EF008255)-
switching function of interval relay with control signal
● flashing symmetrically with pulse start/instantaneousNo
● due to conductor-earth surge according to IEC 61000-4-52 kV
● flashing symmetrically with interval start/instantaneousNo
operating range factor control supply voltage rated value at DC
type of electrical connection for auxiliary and control circuitscrew-type terminals
● due to conductor-conductor surge according to IEC 61000-4-51 kV
electrical endurance (switching cycles) at AC-15 at 230 V typical10 000 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
● retrotriggerable with deactivated control signal/instantaneous contactNo
● retrotriggerable with switched-on control signal/instantaneous contactNo
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
General Product ApprovalDeclaration of ConformityTest CertificatesConfirmationUK Declaration of ConformitySpecial Test CertificateTest CertificatesMarine / ShippingType Test Certificates/Test ReportMarine / ShippingotherRailwayConfirmationVibration and ShockGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top