Service time: Monday to Friday 9:00-18:00
3RA2415-8XF31-1AP0 - 3RA2415-8XF31-1AP0 SIEMENS Contactor assembly for star-delta (wye-delta) start AC-3, 5.5 kW/400 V, 230 V AC ..
In Stock Hot Product

3RA2415-8XF31-1AP0

3RA2415-8XF31-1AP0 SIEMENS Contactor assembly for star-delta (wye-delta) start AC-3, 5.5 kW/400 V, 230 V AC ..

$0.00USD
4772 in stock
Key Specifications
:
EAN:4011209838116
UPC:662643905779
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209838116
UPC662643905779
ETIM5
IDEA4
depth145 mm
width135 mm
UNSPSC14
eClass6
height68 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
● at AC6,7g / 5 ms, 4,2g / 10 ms
● at DC6,7g / 5 ms, 4,2g / 10 ms
Group CodeR711
— upwards6 mm
● at AC-3
Confirmation
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLCO-----
— forwards6 mm
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.85 ... 1.1
Product Group5339
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— backwards0 mm
— downwards6 mm
Commodity Code85364900
Product familySIRIUS 3RA24 contactor assemblies for star-delta (wye-delta) starting, up to 90 kW
last modified:12/1/2021
Net Weight (kg)1,100 Kg
operating power
— at the side6 mm
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
required spacing
Country of originGermany
Marine / Shippingother
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
size of contactorS00
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Function (EF000030)Star-delta contactor
Packaging Dimension221,00 x 306,00 x 87,00
Product DescriptionContactor assembly for star-delta (wye-delta) start AC-3, 5.5 kW/400 V, 230 V AC 50/60 Hz, 3-pole, Size S00 screw terminals electrical and mechanical interlock 3 NO integrated
ambient temperature
product designationContactor assembly for star-delta (wye-delta) start
● during operation-25 ... +60 °C
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (0,5 ... 4 mm²)
● for main contacts
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
General Product ApprovalDeclaration of Conformity
product type designation3RA24
— at 400 V rated value5.5 kW
— at 500 V rated value7.2 kW
— at 690 V rated value9.2 kW
● at 400 V rated value12 A
● at 50 Hz rated value230 V
● at 60 Hz rated value230 V
● of contactor typical10 000 000
● instantaneous contact3
Export Control RegulationsAL : N / ECCN : N
● for auxiliary contacts
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
operational current at AC-3
Package size unit of measureMM
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2009
manufacturer's article number
type of electrical connection
control supply voltage 1 at AC
● with side-by-side mounting
● 1 of the supplied contactor3RT2015-1AP01
● 2 of the supplied contactor3RT2015-1AP01
● 3 of the supplied contactor3RT2015-1AP01
proportion of dangerous failures
shock resistance with sine pulse
product extension auxiliary switchNo
product function bus communicationNo
operating frequency at AC-3 maximum1 000 1/h
● at AWG cables for main contacts2x (20 ... 16), 2x (18 ... 14)
● of the supplied RS assembly kit3RA2913-2BB1
Degree of protection (IP) (EF005474)IP20
Article Number (Market Facing Number)3RA2415-8XF31-1AP0
Rated operation power NEMA (EF011960)-
Voltage type for actuating (EF008242)AC
● for auxiliary and control circuitscrew-type terminals
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit3
— with type of coordination 1 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
contact reliability of auxiliary contacts< 1 error per 100 million operating cycles
mechanical service life (switching cycles)
apparent holding power of magnet coil at AC
apparent pick-up power of magnet coil at AC
protocol is supported AS-Interface protocolNo
number of NO contacts for auxiliary contacts
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
operating voltage at AC-3 rated value maximum690 V
type of voltage of the control supply voltageAC
● with low demand rate according to SN 3192040 %
Rated operation power at AC-3, 400 V (EF001364)5.5
● with high demand rate according to SN 3192075 %
Rated control supply voltage Us at DC (EF003980)['-', '-']
Rated operation current Ie at AC-3, 400 V (EF001392)12
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for short-circuit protection of the main circuit
B10 value with high demand rate according to SN 319201 000 000
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '230']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '230']
inductive power factor with closing power of the coil
installation altitude at height above sea level maximum2 000 m
product function control circuit interface with IO linkNo
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
inductive power factor with the holding power of the coil
● of the supplied function module for wye-delta circuits3RA2816-0EW20
failure rate [FIT] with low demand rate according to SN 31920100 FIT
● of the contactor with added auxiliary switch block typical10 000 000
● for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at AC
General Product ApprovalDeclaration of ConformityTest CertificatesConfirmationUK Declaration of ConformityType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingMarine / ShippingotherRailwayConfirmationVibration and ShockGeneral Product Approval

Product Description

SIRIUS Innovations Star-Triangle AC3, 7, 5KW/400V AC 230V, 50/60 HZ, S00, Enclav screw connection. electrical and mechanical. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide