Service time: Monday to Friday 9:00-18:00
3RA2125-1GH24-0FB4 - 3RA2125-1GH24-0FB4 SIEMENS Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 ..
In Stock Hot Product

3RA2125-1GH24-0FB4

3RA2125-1GH24-0FB4 SIEMENS Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 ..

$0.00USD
4379 in stock
Key Specifications
:
EAN:4047621008653
UPC:Not available
ETIM:7
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621008653
UPCNot available
ETIM7
IDEA4
depth165 mm
width45 mm
UNSPSC15
eClass12
height260 mm
Group CodeR711
trip classCLASS 10
— upwards50 mm
● at AC-3
Confirmation
Metal FactorLCO-----
— forwards20 mm
● at AC-3e
Date6/29/2023Subject to change without notice© Copyright Siemens 2023
Product Group5348
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RA2 load feeders
last modified:4/17/2023
Net Weight (kg)1,650 Kg
operating power
— at the side20 mm
● rated value690 V
Depth (EF000049)165.0
Width (EF000008)45.0
fastening methodfor snapping onto 60 mm busbar systems
required spacing
Country of originGermany
Height (EF000040)260.0
Marine / Shippingother
Test CertificatesMarine / Shipping
mounting positionvertical
operating voltage
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
type of assignment2
● during storage-50 ... +80 °C
● for live parts
Packaging Dimension222,00 x 311,00 x 103,00
Product DescriptionLoad feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front
ambient temperature
operational current
product designationDirect (on-line) starter
size of load feederS0
With fuse (EF006693)false
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productfor 60 mm busbars
protocol is supported
● PROFIsafe protocolNo
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalFor use in hazardous locations
Release class (EF006668)CLASS 10
product type designation3RA21
temperature compensation-20 ... +60 °C
— at 230 V rated value0.75 hp
— at 400 V rated value2 200 W
● PROFINET IO protocolNo
● at 480 V rated value6.3 A
● at 600 V rated value6.3 A
● for 3-phase AC motor
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
size of the circuit-breakerS0
Package size unit of measureMM
control supply voltage at DC
— at 110/120 V rated value0.25 hp
— at 200/208 V rated value1.5 hp
— at 220/230 V rated value1.5 hp
— at 460/480 V rated value3 hp
— at 575/600 V rated value5 hp
● for main current circuitspring-loaded terminals
manufacturer's article number
type of electrical connection
● for single-phase AC motor
● of the supplied contactor3RT2024-2FB40
design of the overload releasethermal (bimetallic)
design of the switching contactelectromechanical
operating frequency rated value50 ... 60 Hz
● at AC-3 rated value maximum690 V
● of the supplied link module3RA2921-2AA00
Type of motor starter (EF009598)Other
degree of protection NEMA ratingother
design of the short-circuit tripmagnetic
● at AC-3 at 400 V rated value6.3 A
● at AC-3e rated value maximum690 V
Rail mounting possible (EF003972)-
● at AC-3e at 400 V rated value6.3 A
External reset possible (EF003426)-
Type Test Certificates/Test ReportSpecial Test Certificate
holding power of magnet coil at DC5.9 W
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
● of the supplied busbar adapter8US1251-5NT11
yielded mechanical performance [hp]
Degree of protection (IP) (EF005474)IP20
surge voltage resistance rated value6 kV
● of the supplied circuit-breakers3RV2021-1GA25
Article Number (Market Facing Number)3RA2125-1GH24-0FB4
Number of indicator lights (EF001965)0
Rated operation current Ie (EF001443)4.9
Voltage type for actuating (EF008242)DC / DC
With short-circuit release (EF006691)true
● for auxiliary and control circuitspring-loaded terminals
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
conditional short-circuit current (Iq)
● without load current share typical5.9 W
number of poles for main current circuit3
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
● at AC in hot operating state per pole2.7 W
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)['4.5', '6.3']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
protocol is supported AS-Interface protocolNo
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
full-load current (FLA) for 3-phase AC motor
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
reference code according to IEC 81346-2:2019Q
shock resistance according to IEC 60068-2-276g / 11 ms
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
power loss [W] for rated value of the current
type of voltage of the control supply voltageDC
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Rated operation power at AC-3, 400 V (EF001364)2.2
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
Rated control supply voltage Us at DC (EF003980)-
Rated operation current at AC-3, 400 V (EF009602)4.9
Supporting protocol for INTERBUS-Safety (EF006662)-
Supporting protocol for DeviceNet Safety (EF007520)-
● at 400 V according to IEC 60947-4-1 rated value150 000 A
Region Specific PriceGroup / Headquarter Price Group41D / 41D
Supporting protocol for other bus systems (EF003062)-
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
Coordination class according to IEC 60947-4-3 (EF012390)Class 2
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Spring clamp connection
type of protection according to ATEX directive 2014/34/EUEx II (2) GD
Supporting protocol for AS-Interface Safety at Work (EF007519)-
insulation voltage with degree of pollution 3 at AC rated value690 V
mechanical service life (operating cycles) of contactor typical10 000 000
response value current of instantaneous short-circuit trip unit82 A
Number of auxiliary contacts as normally open contact (EF001376)1
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
certificate of suitability according to ATEX directive 2014/34/EUDMT 02 ATEX F 001
Number of auxiliary contacts as normally closed contact (EF001377)1
Compliance with the substance restrictions according to RoHS directivenot available
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Type of electrical connection for auxiliary- and control current circuit (EF006979)-
adjustable current response value current of the current-dependent overload release4.5 ... 6.3 A
General Product ApprovalFor use in hazardous locationsDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherRailwayDangerous GoodConfirmationVibration and ShockTransport InformationGeneral Product Approval

Product Description

FUSELESS LOAD FEEDER DIR. START., 400 V AC, SIZE S0 4.50...6.30 TO 24 V DC SPRING-TYPE TERMINALS FOR 60MM BUSBAR SYSTEMS (ALSO FULFILLS T. OF COORD. 1) TYPE OF COORD. 2, IQ = 150 KA 1 NO + 1 NC (CONTA
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top