| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209377929 |
| UPC | Not available |
| Depth | 169 mm |
| Notes | Product is no longer availableSucessor:Successor SIRIUS Innovation 3RA2If you need assistance please contact our local Siemens office |
| Width | 198 mm |
| Height | 140 mm |
| Group Code | R711 |
| Price Group | 41B |
| Metal Factor | LDO----- |
| ● at 50 Hz | 0.8 ... 1.1 |
| ● at 60 Hz | 0.85 ... 1.1 |
| Mounting type | screw fixing |
| Product Group | 3712 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | Not available |
| last modified: | 08/13/2020 |
| Net Weight (kg) | 3,674 Kg |
| — at the side | 0 mm |
| Product function | wye-delta-contactor |
| Required spacing | |
| Country of origin | Germany |
| Operating current | |
| Size of contactor | S2, S2, S2 |
| mounting position | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back |
| ● 1 rated value | 50 Hz |
| ● 2 rated value | 60 Hz |
| ● initial value | 0.8 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| PLM Effective Date | Product discontinued since: 01.04.2020 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● during storage | -55 ... +80 °C |
| ● for live parts | |
| Ambient temperature | |
| Degree of pollution | 3 |
| Function (EF000030) | Star-delta contactor |
| Packaging Dimension | 246,00 x 326,00 x 222,00 |
| Product Description | Contactor assembly Star-delta (wye-delta) (pre-assembled) with lateral timing relay AC-3, 45 kW/400 V, 3-pole Size S2, S2, S2 Electrically interlocked Screw terminal 230 V AC, 50/60 Hz !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2436-8XF32-1AL2<< |
| Product designation | contactor assembly |
| ● leading contact | 0 |
| ● Full-scale value | 1.1 |
| ● during operation | -25 ... +60 °C |
| ● during transport | -55 ... +80 °C |
| Operating power at AC-3 | |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| ● at 400 V rated value | 45 kW |
| ● at 50 Hz rated value | 230 V |
| ● at 500 V rated value | 55 kW |
| ● at 60 Hz rated value | 230 V |
| ● at 690 V rated value | 63 kW |
| ● instantaneous contact | 4 |
| Export Control Regulations | ECCN : N / AL : N |
| Standard lead time ex-works | 20 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| Control supply voltage 1 at AC | |
| Design of the surge suppressor | without |
| Product Dimensions (W x L x H) | Not available |
| control supply voltage frequency | |
| protection class IP on the front | IP20 |
| ● at AC-3 at 400 V rated value | 86 A |
| Product extension Auxiliary switch | Yes |
| ● for grounded parts at the side | 0 mm |
| Degree of protection (IP) (EF005474) | IP20 |
| Article Number (Market Facing Number) | 3RA1436-8XC21-1AL2 |
| Rated operation power NEMA (EF011960) | - |
| Reference code acc. to DIN EN 81346-2 | Q |
| Voltage type for actuating (EF008242) | AC |
| Degree of protection (NEMA) (EF011959) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● with type of assignment 2 required | fuse gL/gG: 80 A |
| Number of NC contacts for main contacts | 0 |
| Number of poles for main current circuit | 3 |
| ● with type of coordination 1 required | fuse gL/gG: 160 A |
| ● with side-by-side mounting at the side | 0 mm |
| Number of NO contacts for auxiliary contacts | |
| Operating voltage at AC-3 rated value maximum | 690 V |
| Type of voltage of the control supply voltage | AC |
| Rated operation power at AC-3, 400 V (EF001364) | 45.0 |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| Control version of the switch operating mechanism | conventional |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 86 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '230'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '230'] |
| Type of electrical connection for main current circuit | screw-type terminals |
| Installation altitude at height above sea level maximum | 2 000 m |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of NC contacts for auxiliary contacts lagging switching | 0 |
| Insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| Design of the fuse link for short-circuit protection of the main circuit | |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Operating range factor control supply voltage rated value of magnet coil at AC | |
| Operating range factor control supply voltage rated value of magnet coil at DC |
Technical specifications and performance data