| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209538597 |
| UPC | Not available |
| ● | |
| Notes | Product is no longer availableSucessor:SIRIUS Innovation 3RA2If you need assistance please contact our local Siemens office |
| depth | 173 mm |
| width | 55 mm |
| height | 295 mm |
| Group Code | R711 |
| Price Group | 41D |
| — upwards | 50 mm |
| Metal Factor | LCO----- |
| — forwards | 10 mm |
| ● stranded | 0.7 ... 35 mm² |
| Product Group | 3709 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| — backwards | 0 mm |
| — downwards | 0 mm |
| Commodity Code | 85364900 |
| Product family | Not available |
| last modified: | 08/29/2020 |
| Net Weight (kg) | 2,080 Kg |
| — at the side | 0 mm |
| ● rated value | 690 V |
| Depth (EF000049) | 173.0 |
| Width (EF000008) | 55.0 |
| required spacing | |
| Country of origin | Germany |
| Height (EF000040) | 295.0 |
| Marine / Shipping | other |
| ● 1 rated value | 50 Hz |
| ● mounting type | snap-on fastening on 35 mm standard rail |
| LKZ_FDB/ CatalogID | CC-IC10 |
| PLM Effective Date | Product discontinued since: 01.04.2020 |
| Packaging Quantity | 1 |
| Type of assignment | 2 |
| insulation voltage | |
| product brand name | SIRIUS |
| ● during storage | -55 ... +80 °C |
| ● for live parts | |
| Packaging Dimension | 65,00 x 302,00 x 192,00 |
| Product Description | Load feeder fuseless direct-on-line starting, 400 V AC 22...32 A, 110 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2 |
| Size of load feeder | S2 |
| ambient temperature | |
| degree of pollution | 3 |
| product designation | non-fused load feeder |
| With fuse (EF006693) | false |
| ● during operation | -20 ... +70 °C |
| ● shock resistance | 8g |
| design of the product | direct starter |
| protocol is supported | |
| ● PROFINET protocol | No |
| ● for main contacts | 30 ... 2 |
| ● mounting position | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
| ● for grounded parts | |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| General Product Approval | For use in hazardous locations |
| Release class (EF006668) | - |
| — at 400 V rated value | 15 kW |
| ● PROFIBUS DP protocol | No |
| ● at 400 V rated value | 50 kA |
| ● at 50 Hz rated value | 110 V |
| Export Control Regulations | ECCN : N / AL : N |
| certificate of suitability | UL / CSA / CCC / GL / LRS / BV / DNV / PRS |
| Standard lead time ex-works | 20 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| ● operating power at AC-3 | |
| Package size unit of measure | MM |
| Type of the motor protection | bimetal |
| ● number of digital inputs | 0 |
| ● single or multi-stranded | 0.7 ... 35 mm² |
| Product Dimensions (W x L x H) | Not available |
| control supply voltage 1 at AC | |
| ● with side-by-side mounting | |
| design of the switching contact | electromechanical |
| ● no-load switching frequency | 15 1/s |
| Type of motor starter (EF009598) | Direct online starter (DOL) |
| control supply voltage frequency | |
| Rail mounting possible (EF003972) | - |
| External reset possible (EF003426) | - |
| product function bus communication | No |
| Degree of protection (IP) (EF005474) | IP20 |
| surge voltage resistance rated value | 6 kV |
| ● protection class IP on the front | IP20 |
| Article Number (Market Facing Number) | 3RA1130-4EB34-0AF0 |
| Number of indicator lights (EF001965) | 0 |
| Rated operation current Ie (EF001443) | 29 |
| Voltage type for actuating (EF008242) | AC / #NO_DATA# |
| With short-circuit release (EF006691) | true |
| reference code acc. to DIN EN 81346-2 | Q |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● design of short-circuit protection | circuit-breakers |
| ● product extension auxiliary switch | Yes |
| number of poles for main current circuit | 3 |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| product function short circuit protection | Yes |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | ['22', '32'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| ● finely stranded with core end processing | 0.75 ... 25 mm² |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| type of voltage of the control supply voltage | AC |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| Rated operation power at AC-3, 400 V (EF001364) | 15.0 |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| ● protocol is supported AS-Interface protocol | No |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| ● number of CO contacts for auxiliary contacts | 0 |
| ● number of NC contacts for auxiliary contacts | 0 |
| ● number of NO contacts for auxiliary contacts | 0 |
| Rated operation current at AC-3, 400 V (EF009602) | 29 |
| ● operating voltage at AC-3 rated value maximum | 400 V |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| — operating current at AC-3 at 400 V rated value | 29 A |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Supporting protocol for other bus systems (EF003062) | - |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| connectable conductor cross-section for main contacts | |
| maximum short-circuit current breaking capacity (Icu) | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| AWG number as coded connectable conductor cross section | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| ● type of electrical connection for main current circuit | screw-type terminals |
| ● Manufacturer's article number of the supplied contactor | 3RT1034-1AF00 |
| ● installation altitude at height above sea level maximum | 2 000 m |
| ● manufacturer's article number of the supplied link module | 3RA1931-1AA00 |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| ● Manufacturer's article number of the supplied circuit-breakers | 3RV1031-4EA10 |
| ● mechanical service life (switching cycles) of contactor typical | 10 000 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| ● type of connectable conductor cross-sections for main contacts solid | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) |
| adjustable pick-up value current of the current-dependent overload release | 22 ... 32 A |
| ● Type of connectable conductor cross-sections for main contacts stranded | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) |
| ● Manufacturer's article number of the supplied standard mounting rail adapter | 3RA1932-1AA00 |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - |
| ● type of connectable conductor cross-sections at AWG conductors for main contacts | 2x (30 ... 2) |
| ● type of connectable conductor cross-sections for main contacts finely stranded with core end processing | 0.75 ... 25 mm², 2x (0.75 ... 16 mm²) |
| General Product ApprovalFor use in hazardous locationsDeclaration of ConformityMarine / ShippingMiscellaneousMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide