Service time: Monday to Friday 9:00-18:00
3RA1130-4EB34-0AF0 - 3RA1130-4EB34-0AF0 SIEMENS Load feeder fuseless direct-on-line starting, 400 V AC 22...32 A, 110 V AC 50 Hz ..
In Stock Hot Product

3RA1130-4EB34-0AF0

3RA1130-4EB34-0AF0 SIEMENS Load feeder fuseless direct-on-line starting, 400 V AC 22...32 A, 110 V AC 50 Hz ..

$0.00USD
4535 in stock
Key Specifications
:Value
EAN:4011209538597
UPC:Not available
●:
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209538597
UPCNot available
NotesProduct is no longer availableSucessor:SIRIUS Innovation 3RA2If you need assistance please contact our local Siemens office
depth173 mm
width55 mm
height295 mm
Group CodeR711
Price Group41D
— upwards50 mm
Metal FactorLCO-----
— forwards10 mm
● stranded0.7 ... 35 mm²
Product Group3709
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— backwards0 mm
— downwards0 mm
Commodity Code85364900
Product familyNot available
last modified:08/29/2020
Net Weight (kg)2,080 Kg
— at the side0 mm
● rated value690 V
Depth (EF000049)173.0
Width (EF000008)55.0
required spacing
Country of originGermany
Height (EF000040)295.0
Marine / Shippingother
● 1 rated value50 Hz
● mounting typesnap-on fastening on 35 mm standard rail
LKZ_FDB/ CatalogIDCC-IC10
PLM Effective DateProduct discontinued since: 01.04.2020
Packaging Quantity1
Type of assignment2
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
Packaging Dimension65,00 x 302,00 x 192,00
Product DescriptionLoad feeder fuseless direct-on-line starting, 400 V AC 22...32 A, 110 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2
Size of load feederS2
ambient temperature
degree of pollution3
product designationnon-fused load feeder
With fuse (EF006693)false
● during operation-20 ... +70 °C
● shock resistance8g
design of the productdirect starter
protocol is supported
● PROFINET protocolNo
● for main contacts30 ... 2
● mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
● for grounded parts
Product Lifecycle (PLM)PM490:Start of final year of support
General Product ApprovalFor use in hazardous locations
Release class (EF006668)-
— at 400 V rated value15 kW
● PROFIBUS DP protocolNo
● at 400 V rated value50 kA
● at 50 Hz rated value110 V
Export Control RegulationsECCN : N / AL : N
certificate of suitabilityUL / CSA / CCC / GL / LRS / BV / DNV / PRS
Standard lead time ex-works20 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
● operating power at AC-3
Package size unit of measureMM
Type of the motor protectionbimetal
● number of digital inputs0
● single or multi-stranded0.7 ... 35 mm²
Product Dimensions (W x L x H)Not available
control supply voltage 1 at AC
● with side-by-side mounting
design of the switching contactelectromechanical
● no-load switching frequency15 1/s
Type of motor starter (EF009598)Direct online starter (DOL)
control supply voltage frequency
Rail mounting possible (EF003972)-
External reset possible (EF003426)-
product function bus communicationNo
Degree of protection (IP) (EF005474)IP20
surge voltage resistance rated value6 kV
● protection class IP on the frontIP20
Article Number (Market Facing Number)3RA1130-4EB34-0AF0
Number of indicator lights (EF001965)0
Rated operation current Ie (EF001443)29
Voltage type for actuating (EF008242)AC / #NO_DATA#
With short-circuit release (EF006691)true
reference code acc. to DIN EN 81346-2Q
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)false
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● design of short-circuit protectioncircuit-breakers
● product extension auxiliary switchYes
number of poles for main current circuit3
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)['22', '32']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
● finely stranded with core end processing0.75 ... 25 mm²
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
type of voltage of the control supply voltageAC
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Rated operation power at AC-3, 400 V (EF001364)15.0
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
● protocol is supported AS-Interface protocolNo
Rated control supply voltage Us at DC (EF003980)['-', '-']
● number of CO contacts for auxiliary contacts0
● number of NC contacts for auxiliary contacts0
● number of NO contacts for auxiliary contacts0
Rated operation current at AC-3, 400 V (EF009602)29
● operating voltage at AC-3 rated value maximum400 V
Supporting protocol for INTERBUS-Safety (EF006662)-
— operating current at AC-3 at 400 V rated value29 A
Supporting protocol for DeviceNet Safety (EF007520)-
Supporting protocol for other bus systems (EF003062)-
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
connectable conductor cross-section for main contacts
maximum short-circuit current breaking capacity (Icu)
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
AWG number as coded connectable conductor cross section
Coordination class according to IEC 60947-4-3 (EF012390)Class 2
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Screw connection
● type of electrical connection for main current circuitscrew-type terminals
● Manufacturer's article number of the supplied contactor3RT1034-1AF00
● installation altitude at height above sea level maximum2 000 m
● manufacturer's article number of the supplied link module3RA1931-1AA00
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)0
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
Number of auxiliary contacts as normally closed contact (EF001377)0
● Manufacturer's article number of the supplied circuit-breakers3RV1031-4EA10
● mechanical service life (switching cycles) of contactor typical10 000 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● type of connectable conductor cross-sections for main contacts solid0.7 ... 35 mm², 2x (0.75 ... 25 mm²)
adjustable pick-up value current of the current-dependent overload release22 ... 32 A
● Type of connectable conductor cross-sections for main contacts stranded0.7 ... 35 mm², 2x (0.75 ... 25 mm²)
● Manufacturer's article number of the supplied standard mounting rail adapter3RA1932-1AA00
Type of electrical connection for auxiliary- and control current circuit (EF006979)-
● type of connectable conductor cross-sections at AWG conductors for main contacts2x (30 ... 2)
● type of connectable conductor cross-sections for main contacts finely stranded with core end processing0.75 ... 25 mm², 2x (0.75 ... 16 mm²)
General Product ApprovalFor use in hazardous locationsDeclaration of ConformityMarine / ShippingMiscellaneousMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top