Service time: Monday to Friday 9:00-18:00
3NP1143-1BC12 - 3NP1143-1BC12 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH1, 250 A, for Busbar system 8US 60 m..
In Stock Hot Product

3NP1143-1BC12

3NP1143-1BC12 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH1, 250 A, for Busbar system 8US 60 m..

$0.00USD
3966 in stock
Key Specifications
:
EAN:4011209761490
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209761490
UPCNot available
ETIM5
depth172.5 mm
width183.7 mm
UNSPSC14
eClass6
height306 mm
● openIP20
Group CodeP360
net weight2.99 kg
fuse systemLV HRC fuse
● maximum12 N·m
● minimum10 N·m
Date5/5/2022
Metal FactorLCP-----
power factor
Product Group5863
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
busbar designbusbar thickness 5 or 10 mm
Commodity Code85362090
Product familyBasic Devices
power loss [W]
type of deviceFor 60 mm 8US busbar system
● at AC-22 B0.65
● at AC-23 B0.45
Net Weight (kg)3,560 Kg
number of poles3
● main switchNo
● motor driveNo
● rated value690 V
fastening methodbusbar
product function
● on the frontIP40
Country of originCzech Republic
mounting positionhorizontal/vertical
operating voltage
size of fuse linkNH0, NH1
● rail mountingYes
● safety switchYes
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
insulation voltage
product brand nameSENTRON
● floor mountingNo
Packaging Dimension203,00 x 389,00 x 267,00
Product DescriptionSENTRON, Fuse switch disconnector 3NP1, 3-pole, NH1, 250 A, for Busbar system 8US 60 mm, flat terminal, Fuse monitoring: electronic EFM10, Cover level 32/70 mm
degree of pollution2
operational current
product designation3NP1 fuse switch disconnector
protection class IP
suitability for use
● fuse monitoringYes
● voltage triggerNo
design of the productcover level 32/70 mm
Cable entry (EF000537)-
● locking capabilityYes
● stranded / maximum150 mm²
● stranded / minimum16 mm²
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value250 A
● switch disconnectorYes
● EMERGENCY OFF switchNo
● with capacitive load-0.25
Declaration of ConformityTest Certificates
power factor / at AC-21 B0.95
● 4-hole front mountingNo
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
product feature / sealableYes
size of disconnecting link1 and 0
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
product feature / interlockYes
● at 35 °C / rated value250 A
● at 40 °C / rated value245 A
● at 45 °C / rated value240 A
● at 50 °C / rated value233 A
● at 55 °C / rated value233 A
Package size unit of measureMM
UK Declaration of Conformity
product extension / optional
● phase failure monitoringYes
Suitable for fuses (EF006692)NH0, NH1
type of connection technologyFlat terminal
● maintenance/repair switchYes
Motor drive optional (EF007386)false
busbar center-to-center spacing60 mm
design of the actuating elementCover handle
design of the safety monitoringelectronic EFM 10
● solid or stranded / maximum150 mm²
● solid or stranded / minimum16 mm²
With error protection (EF007384)true
Motor drive integrated (EF006697)false
Version as main switch (EF006981)false
● at AC / rated value / maximum690 V
● at AC / rated value / minimum230 V
Type of control element (EF006976)Cover grip
Equipped with connectors (EF011696)false
Position control element (EF009410)Front side
Version as safety switch (EF006985)true
ambient temperature / during storage
product extension / auxiliary switchYes
● of the fuse / per fuse / maximum23 W
Article Number (Market Facing Number)3NP1143-1BC12
Rated permanent current Iu (EF001389)250.0
● overvoltage protection monitoringYes
Suitable for floor mounting (EF007243)false
Suitable for front mounting (EF007246)false
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
design of the load switch / strip formNo
surge voltage resistance / rated value8 kV
● product component / trip indicatorYes
Suitable for busbar mounting (EF007259)true
● at AC-21 B / at 240 V / rated value250 A
● at AC-21 B / at 400 V / rated value250 A
● at AC-21 B / at 500 V / rated value250 A
● at AC-21 B / at 690 V / rated value250 A
● at AC-22 B / at 240 V / rated value250 A
● at AC-22 B / at 400 V / rated value250 A
● at AC-22 B / at 500 V / rated value250 A
● at AC-22 B / at 690 V / rated value250 A
● at AC-23 B / at 240 V / rated value250 A
● at AC-23 B / at 400 V / rated value250 A
● at AC-23 B / at 500 V / rated value200 A
● at AC-23 B / at 690 V / rated value100 A
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
● product component / undervoltage releaseNo
Max. rated operation voltage Ue AC (EF007355)690
tightening torque / with screw-type terminals
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
● product function / phase failure monitoringNo
Degree of protection (IP), front side (EF003118)IP40
Rated operation power at AC-23, 400 V (EF007027)-
Rated short-time withstand current lcw (EF007050)-
Version as emergency stop installation (EF006959)false
● with capacitive load / at 400 V / rated value72 A
● with capacitive load / at 500 V / rated value55 A
Region Specific PriceGroup / Headquarter Price Group14M / 1DL
mechanical service life (switching cycles) / typical1 600
● with degree of pollution 2 / at AC / rated value1 000 V
● with degree of pollution 3 / at AC / rated value690 V
Conditioned rated short-circuit current Iq (EF001444)80.0
● with closed switch / with cover or cable lug coverIP40
connectable conductor cross-section / for main contacts
Type of electrical connection of main circuit (EF006819)Rail connection
type of electrical connection / for main current circuitbusbar connection
● with closed switch / without cover or cable lug coverIP30
let-through current / with closed switch / maximum permissible32 kA
arrangement of electrical connectors / for main current circuitother
● product component / undervoltage release with leading contactNo
● with conventional rated thermal current / without fuse / per pole8 W
Compliance with the substance restrictions according to RoHS directiveSince: 23.10.2008
let-through current / with high-speed activation / maximum permissible25 kA
● with conventional rated thermal current / without fuse / per device24 W
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● for rated value of the current / at AC / in hot operating state / per pole31 W
type of connectable conductor cross-sections / of the laminated conductors / maximum25 x 18 mm
General Product ApprovalConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformityType Test Certificates/Test ReportMiscellaneousGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top