| Parameter | Value |
|---|---|
| EAN | 4011209700291 |
| UPC | 040892997507 |
| ETIM | 5 |
| depth | 134.5 mm |
| width | 105.8 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 215.1 mm |
| ● open | IP20 |
| Group Code | P360 |
| net weight | 0.98 kg |
| fuse system | LV HRC fuse |
| ● maximum | 12 N·m |
| ● minimum | 10 N·m |
| Confirmation | |
| Date5/4/2022 | |
| Metal Factor | LCP----- |
| power factor | |
| Product Group | 5863 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| busbar design | busbar thickness 5 or 10 mm |
| Commodity Code | 85362090 |
| Product family | Basic Devices |
| power loss [W] | |
| type of device | For Rittal 60 mm busbar system |
| ● at AC-22 B | 0.65 |
| ● at AC-23 B | 0.45 |
| Net Weight (kg) | 1,071 Kg |
| number of poles | 3 |
| ● main switch | No |
| ● motor drive | No |
| ● rated value | 690 V |
| fastening method | busbar |
| product function | |
| ● on the front | IP40 |
| Country of origin | Czech Republic |
| mounting position | horizontal/vertical |
| operating voltage | |
| size of fuse link | NH000, NH00 |
| ● rail mounting | Yes |
| ● safety switch | Yes |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| insulation voltage | |
| product brand name | SENTRON |
| ● floor mounting | No |
| Packaging Dimension | 154,00 x 230,00 x 118,00 |
| Product Description | SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Rittal busbar system 60 mm, flat terminal, Cover level 32/70 mm |
| degree of pollution | 3 |
| operational current | |
| product designation | 3NP1 fuse switch disconnector |
| protection class IP | |
| suitability for use | |
| ● fuse monitoring | Yes |
| ● voltage trigger | No |
| design of the product | cover level 32/70 mm |
| Cable entry (EF000537) | - |
| ● locking capability | Yes |
| ● stranded / maximum | 95 mm² |
| ● stranded / minimum | 2.5 mm² |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AC / rated value | 160 A |
| ● at DC / rated value | 440 V |
| ● switch disconnector | Yes |
| General Product Approval | Declaration of Conformity |
| ● EMERGENCY OFF switch | No |
| ● with capacitive load | -0.25 |
| Declaration of Conformity | Test Certificates |
| power factor / at AC-21 B | 0.95 |
| ● 4-hole front mounting | No |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Number of poles (EF001391) | 3 |
| product feature / sealable | Yes |
| size of disconnecting link | 00 and 000 |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| product feature / interlock | Yes |
| ● at 35 °C / rated value | 160 A |
| ● at 40 °C / rated value | 155 A |
| ● at 45 °C / rated value | 145 A |
| ● at 50 °C / rated value | 140 A |
| ● at 55 °C / rated value | 133 A |
| Package size unit of measure | MM |
| product extension / optional | |
| ● phase failure monitoring | Yes |
| Suitable for fuses (EF006692) | NH000, NH00 |
| type of connection technology | Flat terminal |
| ● maintenance/repair switch | Yes |
| Motor drive optional (EF007386) | false |
| busbar center-to-center spacing | 60 mm |
| design of the actuating element | Cover handle |
| design of the safety monitoring | Without |
| ● solid or stranded / maximum | 95 mm² |
| ● solid or stranded / minimum | 2.5 mm² |
| With error protection (EF007384) | false |
| Motor drive integrated (EF006697) | false |
| Version as main switch (EF006981) | false |
| ● at AC / rated value / maximum | 690 V |
| ● at DC / rated value / maximum | 440 V |
| Type of control element (EF006976) | Cover grip |
| Equipped with connectors (EF011696) | false |
| Position control element (EF009410) | Front side |
| Version as safety switch (EF006985) | true |
| ambient temperature / during storage | |
| product extension / auxiliary switch | Yes |
| ● of the fuse / per fuse / maximum | 12 W |
| Article Number (Market Facing Number) | 3NP1133-1JC10 |
| Rated permanent current Iu (EF001389) | 160.0 |
| ● overvoltage protection monitoring | Yes |
| Suitable for floor mounting (EF007243) | false |
| Suitable for front mounting (EF007246) | false |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ambient temperature / during operation | |
| design of the load switch / strip form | No |
| surge voltage resistance / rated value | 8 kV |
| ● product component / trip indicator | No |
| Suitable for busbar mounting (EF007259) | true |
| ● at AC-21 B / at 240 V / rated value | 160 A |
| ● at AC-21 B / at 400 V / rated value | 160 A |
| ● at AC-21 B / at 500 V / rated value | 160 A |
| ● at AC-21 B / at 690 V / rated value | 160 A |
| ● at AC-22 B / at 240 V / rated value | 160 A |
| ● at AC-22 B / at 400 V / rated value | 160 A |
| ● at AC-22 B / at 500 V / rated value | 160 A |
| ● at AC-22 B / at 690 V / rated value | 125 A |
| ● at AC-23 B / at 240 V / rated value | 160 A |
| ● at AC-23 B / at 400 V / rated value | 160 A |
| ● at AC-23 B / at 500 V / rated value | 63 A |
| ● at AC-23 B / at 690 V / rated value | 35 A |
| ● at DC-21 B / at 120 V / rated value | 160 A |
| ● at DC-21 B / at 240 V / rated value | 160 A |
| ● at DC-21 B / at 440 V / rated value | 160 A |
| ● at DC-22 B / at 120 V / rated value | 160 A |
| ● at DC-22 B / at 240 V / rated value | 160 A |
| ● at DC-22 B / at 440 V / rated value | 125 A |
| ● at DC-23 B / at 120 V / rated value | 100 A |
| ● at DC-23 B / at 240 V / rated value | 100 A |
| ● at DC-23 B / at 440 V / rated value | 63 A |
| ● front mounting with central attachment | No |
| type of the driving mechanism / motor drive | No |
| ● product component / undervoltage release | No |
| Max. rated operation voltage Ue AC (EF007355) | 690 |
| tightening torque / with screw-type terminals | |
| number of CO contacts / for auxiliary contacts | 0 |
| number of NC contacts / for auxiliary contacts | 0 |
| number of NO contacts / for auxiliary contacts | 0 |
| ● product function / phase failure monitoring | No |
| Degree of protection (IP), front side (EF003118) | IP40 |
| Rated operation power at AC-23, 400 V (EF007027) | - |
| Rated short-time withstand current lcw (EF007050) | - |
| Version as emergency stop installation (EF006959) | false |
| ● with capacitive load / at 400 V / rated value | 72 A |
| ● with capacitive load / at 500 V / rated value | 55 A |
| Region Specific PriceGroup / Headquarter Price Group | 14M / 1DL |
| mechanical service life (switching cycles) / typical | 2 000 |
| ● with degree of pollution 2 / at AC / rated value | 1 000 V |
| ● with degree of pollution 3 / at AC / rated value | 690 V |
| Conditioned rated short-circuit current Iq (EF001444) | 80.0 |
| ● with closed switch / with cover or cable lug cover | IP40 |
| connectable conductor cross-section / for main contacts | |
| Type of electrical connection of main circuit (EF006819) | Rail connection |
| type of electrical connection / for main current circuit | busbar connection |
| ● with closed switch / without cover or cable lug cover | IP30 |
| let-through current / with closed switch / maximum permissible | 23 kA |
| arrangement of electrical connectors / for main current circuit | other |
| ● product component / undervoltage release with leading contact | No |
| ● with conventional rated thermal current / without fuse / per pole | 5 W |
| Compliance with the substance restrictions according to RoHS directive | Since: 23.10.2008 |
| let-through current / with high-speed activation / maximum permissible | 15 kA |
| ● with conventional rated thermal current / without fuse / per device | 15 W |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| ● for rated value of the current / at AC / in hot operating state / per pole | 17 W |
| type of connectable conductor cross-sections / of the laminated conductors / maximum | 24 x 12 mm |
| General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityTest CertificatesMarine / ShippingotherSpecial Test CertificateType Test Certificates/Test ReportMiscellaneous | General Product Approval |
Technical specifications and performance data