Service time: Monday to Friday 9:00-18:00
3NP1133-1BB10 - 3NP1133-1BB10 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 40 ..
In Stock Hot Product

3NP1133-1BB10

3NP1133-1BB10 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 40 ..

$0.00USD
3046 in stock
Key Specifications
:
EAN:4011209700253
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209700253
UPCNot available
ETIM5
depth137.8 mm
width105.8 mm
UNSPSC14
eClass6
height210.4 mm
● openIP20
Group CodeP360
net weight0.98 kg
fuse systemLV HRC fuse
● maximum12 N·m
● minimum10 N·m
Confirmation
Metal FactorLCP-----
power factor
Date5/18/2022
Miscellaneous
Product Group5863
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
busbar designbusbar thickness 5 or 10 mm
Commodity Code85362090
Product familyBasic Devices
power loss [W]
type of deviceFor 40 mm 8US busbar system
● at AC-22 B0.65
● at AC-23 B0.45
Net Weight (kg)1,092 Kg
number of poles3
● main switchNo
● motor driveNo
● rated value690 V
fastening methodbusbar
product function
● on the frontIP40
Country of originCzech Republic
mounting positionhorizontal/vertical
operating voltage
size of fuse linkNH000, NH00
● rail mountingYes
● safety switchYes
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
insulation voltage
product brand nameSENTRON
● floor mountingNo
Packaging Dimension150,00 x 228,00 x 118,00
Product DescriptionSENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 40 mm, flat terminal, Cover level 32/70 mm
degree of pollution3
operational current
product designation3NP1 fuse switch disconnector
protection class IP
suitability for use
● fuse monitoringYes
● voltage triggerNo
design of the productcover level 32/70 mm
Cable entry (EF000537)-
● locking capabilityYes
● stranded / maximum95 mm²
● stranded / minimum2.5 mm²
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value160 A
● at DC / rated value440 V
● switch disconnectorYes
● EMERGENCY OFF switchNo
● with capacitive load-0.25
Declaration of ConformityTest Certificates
power factor / at AC-21 B0.95
● 4-hole front mountingNo
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
product feature / sealableYes
size of disconnecting link00 and 000
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
product feature / interlockYes
● at 35 °C / rated value160 A
● at 40 °C / rated value155 A
● at 45 °C / rated value145 A
● at 50 °C / rated value140 A
● at 55 °C / rated value133 A
Package size unit of measureMM
UK Declaration of Conformity
product extension / optional
● phase failure monitoringYes
Suitable for fuses (EF006692)NH000, NH00
type of connection technologyFlat terminal
● maintenance/repair switchYes
Motor drive optional (EF007386)false
busbar center-to-center spacing40 mm
design of the actuating elementCover handle
design of the safety monitoringWithout
● solid or stranded / maximum95 mm²
● solid or stranded / minimum2.5 mm²
With error protection (EF007384)false
Motor drive integrated (EF006697)false
Version as main switch (EF006981)false
● at AC / rated value / maximum690 V
● at DC / rated value / maximum440 V
Type of control element (EF006976)Cover grip
Equipped with connectors (EF011696)false
Position control element (EF009410)Front side
Version as safety switch (EF006985)true
ambient temperature / during storage
product extension / auxiliary switchYes
● of the fuse / per fuse / maximum12 W
Article Number (Market Facing Number)3NP1133-1BB10
Rated permanent current Iu (EF001389)160.0
● overvoltage protection monitoringYes
Suitable for floor mounting (EF007243)false
Suitable for front mounting (EF007246)false
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
design of the load switch / strip formNo
surge voltage resistance / rated value8 kV
● product component / trip indicatorNo
Suitable for busbar mounting (EF007259)true
● at AC-21 B / at 240 V / rated value160 A
● at AC-21 B / at 400 V / rated value160 A
● at AC-21 B / at 500 V / rated value160 A
● at AC-21 B / at 690 V / rated value160 A
● at AC-22 B / at 240 V / rated value160 A
● at AC-22 B / at 400 V / rated value160 A
● at AC-22 B / at 500 V / rated value160 A
● at AC-22 B / at 690 V / rated value125 A
● at AC-23 B / at 240 V / rated value160 A
● at AC-23 B / at 400 V / rated value160 A
● at AC-23 B / at 500 V / rated value63 A
● at AC-23 B / at 690 V / rated value35 A
● at DC-21 B / at 120 V / rated value160 A
● at DC-21 B / at 240 V / rated value160 A
● at DC-21 B / at 440 V / rated value160 A
● at DC-22 B / at 120 V / rated value160 A
● at DC-22 B / at 240 V / rated value160 A
● at DC-22 B / at 440 V / rated value125 A
● at DC-23 B / at 120 V / rated value100 A
● at DC-23 B / at 240 V / rated value100 A
● at DC-23 B / at 440 V / rated value63 A
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
● product component / undervoltage releaseNo
Max. rated operation voltage Ue AC (EF007355)690
tightening torque / with screw-type terminals
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
● product function / phase failure monitoringNo
Degree of protection (IP), front side (EF003118)IP40
Rated operation power at AC-23, 400 V (EF007027)-
Rated short-time withstand current lcw (EF007050)-
Version as emergency stop installation (EF006959)false
● with capacitive load / at 400 V / rated value72 A
● with capacitive load / at 500 V / rated value55 A
Region Specific PriceGroup / Headquarter Price Group14M / 1DL
mechanical service life (switching cycles) / typical2 000
● with degree of pollution 2 / at AC / rated value1 000 V
● with degree of pollution 3 / at AC / rated value690 V
Conditioned rated short-circuit current Iq (EF001444)80.0
● with closed switch / with cover or cable lug coverIP40
connectable conductor cross-section / for main contacts
Type of electrical connection of main circuit (EF006819)Rail connection
type of electrical connection / for main current circuitbusbar connection
● with closed switch / without cover or cable lug coverIP30
let-through current / with closed switch / maximum permissible23 kA
arrangement of electrical connectors / for main current circuitother
● product component / undervoltage release with leading contactNo
● with conventional rated thermal current / without fuse / per pole5 W
Compliance with the substance restrictions according to RoHS directiveSince: 23.10.2008
let-through current / with high-speed activation / maximum permissible15 kA
● with conventional rated thermal current / without fuse / per device15 W
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● for rated value of the current / at AC / in hot operating state / per pole17 W
type of connectable conductor cross-sections / of the laminated conductors / maximum24 x 12 mm
General Product ApprovalConfirmationMiscellaneousDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportotherMiscellaneousGeneral Product Approval

Product Description

UNDER-LOAD DISCONNECTOR WITH 3-POLE, NH00, 160A FUSES FOR 40MM BUSBAR SYSTEMS
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top