Key Specifications
:
EAN:4011209790520
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209790520
UPCNot available
ETIM5
depth195 mm
width99.5 mm
eClass6
height662 mm
● 40 mmNo
● 50 mmNo
● 60 mmNo
Group CodeP360
net weight25.52 kg
● 100 mmNo
● 185 mmYes
fuse systemLV HRC fuse
● maximum55 °C
● minimum-25 °C
Confirmation
Date5/5/2022
Metal Factor-43-----
Product Group5852
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85389099
Product family3-pole, Switchable
type of deviceFor busbar system 185 mm
Net Weight (kg)25,520 Kg
number of poles3
● main switchNo
● rated value1 444 A
Model (EF000010)Fuse switch disconnector
fastening methodFlachanschluss, 4 x M 12
Country of originGermany
mounting positionvertical
product component
size of fuse linkNH3
● safety switchNo
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
product brand nameSENTRON
Packaging Dimension230,00 x 9850,00 x 240,00
Product DescriptionFuse switch disconnector 3-pole selectable, for protection of transformers on the secondary side up to 1000 kVA for LV HRC fuses GTR 2x722 A max., 400 V AC, and NH3 disconnecting blade up to 2000 A
operational current
product designationFuse switch disconnectors
suitability for use
● voltage triggerNo
design of the productin in-line design
number of poles / note3-pole switchable
number of transformers0
Product Lifecycle (PLM)PM300:Active Product
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
● EMERGENCY OFF switchNo
● undervoltage releaseNo
suitability for operationTransformer protection
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
Standard lead time ex-works15 Day/Days
Surcharge for Raw MaterialsNone
● at 35 °C / rated value1 444 A
● at 40 °C / rated value1 271.5 A
● at 45 °C / rated value1 299.5 A
● at 50 °C / rated value1 227 A
● at 55 °C / rated value1 155 A
● at 60 °C / rated value1 083 A
● at 65 °C / rated value1 010 A
● at 70 °C / rated value938.5 A
Package size unit of measureMM
Release indication (EF011943)-
● maintenance/repair switchNo
Double interrupting (EF007103)false
busbar center-to-center spacing185 mm
design of the auxiliary releaseWithout
design of the safety monitoringWithout
insulation voltage / rated value690 V
protection class IP / on the frontIP30
Article Number (Market Facing Number)3NJ4173-3BF01
Rated permanent current Iu (EF001389)1444.0
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
design of the load switch / strip formYes
Construction size fuse insert (EF001452)NH3
Max. rated operation voltage Ue AC (EF007355)400
● undervoltage release with leading contactNo
Distance between rail centre, 40 mm (EF001431)false
Distance between rail centre, 50 mm (EF001430)false
Distance between rail centre, 60 mm (EF001432)false
Distance between rail centre, 100 mm (EF006048)false
Distance between rail centre, 185 mm (EF006049)true
● with capacitive load / at 400 V / rated value810 A
● with capacitive load / at 500 V / rated value600 A
Region Specific PriceGroup / Headquarter Price Group14M / 1DL
Conditioned rated short-circuit current Iq (EF001444)-
Type of electrical connection of main circuit (EF006819)Rail connection
type of electrical connection / for main current circuitbusbar connection
type of switching contact / double breaking switching contactNo
arrangement of electrical connectors / for main current circuitFlat terminal
Compliance with the substance restrictions according to RoHS directiveSince: 17.04.2009
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
power loss [W] / for rated value of the current / at AC / in hot operating state / per pole173 W
General Product ApprovalDeclaration of ConformityotherConfirmationUK Declaration of ConformityMiscellaneousGeneral Product Approval

Product Description

BATON ALIMENT., I=910A, U=690V FOR SPECIAL FUSES, P. PROT. TAM TRANSPARAMATOR. NH3 3-POLE SWITCHABLE NEW DESIGN. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top