Key Specifications
:Confirmation
EAN:4011209860254
UPC:Not available
depth:361 mm
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209860254
UPCNot available
depth361 mm
width71 mm
height105 mm
● solid1x (4...50mm²)
Group CodeP360
net weight725 g
● maximum1
● minimum12
Metal FactorLAO-----
● stranded1x (4...50mm²)
Date5/15/2022
Product Group5887
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85365080
Product familyNot available
power loss [W]
type of devicefixed mounting
type of switchFloor mounting with door coupling
Net Weight (kg)0,599 Kg
number of poles3
operating power
product feature
● main switchYes
● motor driveNo
design of handlerotary operating mechanism, red/yellow
fastening methodBuilt-in unit fixed-mounted version
Country of originGermany
● rail mountingYes
● safety switchYes
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
product brand nameSENTRON
Packaging Dimension103,00 x 163,00 x 122,00
Product DescriptionSENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 125 A, operating power / at AC-23 A 400 V: 45 kW, floor mounting with door coupling, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle, without tolerance compensation, Installation dimension 138.5 mm, Handle rotated by 90°
operational current
product designation3LD Switch disconnector
protection class IPIP65
suitability for use
● voltage triggerNo
design of the productEMERGENCY-STOP switch
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
special product featureWithout tolerance compensation, installation dimension 138.5 mm, handle rotated 90°
● at AC / rated value125 A
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
● EMERGENCY OFF switchYes
● 4-hole front mountingYes
● at AC-23 A / at 690 V6 000
Export Control RegulationsECCN : N / AL : N
● for auxiliary contactsconnection terminals
Environmental Confirmations
Standard lead time ex-works130 Day/Days
Surcharge for Raw MaterialsNone
size of switch disconnector4
● at 40 °C / rated value125 A
● at 45 °C / rated value125 A
● at 50 °C / rated value125 A
● at 55 °C / rated value125 A
Package size unit of measureMM
product extension / optional
● for main current circuitbox terminal
operating frequency / maximum50 1/h
type of electrical connection
● maintenance/repair switchYes
type of fuse / according to ULRK5
design of the actuating elementShort rotary knob
color / of the actuating elementred
degree of protection NEMA rating1, 3R, 4X, 12
insulation voltage / rated value690 V
number of bracket locks / maximum3
operational current / rated value125 A
protection class IP / on the frontIP65
● can be locked into OFF positionYes
● at AC-3 / at 240 V / rated value22 kW
● at AC-3 / at 400 V / rated value37 kW
● at AC-3 / at 690 V / rated value30 kW
Article Number (Market Facing Number)3LD2816-0TK53-0AG1
● at AC-21 / at 690 V / rated value125 A
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
surge voltage resistance / rated value6 kV
electrical endurance (switching cycles)
● at 690 V / by gG fuse / rated value20 kA
● at AC-21 A / at 240 V / rated value125 A
● at AC-21 A / at 440 V / rated value125 A
● at AC-23 A / at 240 V / rated value22 kW
● at AC-23 A / at 400 V / rated value80 A
● at AC-23 A / at 440 V / rated value45 kW
● at AC-23 A / at 690 V / rated value37 kW
let-through current / with closed switch
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
ambient temperature / during storage / minimum-25 °C
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
● finely stranded / with core end processing1x (4...35mm²)
hasp thickness / of the bracket locks / maximum8 mm
hasp thickness / of the bracket locks / minimum4 mm
Region Specific PriceGroup / Headquarter Price Group12R / 1CL
mechanical service life (switching cycles) / typical100 000
operational current / of upstream fuse / rated value125 A
● at 440 V / for combination switch + gG fuse / maximum10 kA
insulation voltage / of the auxiliary switch / rated value500 V
continuous current / of the auxiliary contact / rated value10 A
operating voltage / of auxiliary contacts / at AC / maximum500 V
display version / for switch position indicator manual operation1 ON - 0 OFF
AWG number / as coded connectable conductor cross section / solid
conditional short-circuit current / with line-side fuse protection
type of connectable conductor cross-sections / for copper conductor
● for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
continuous current / of upstream fuse / according to UL / rated value200 A
type of connectable conductor cross-sections / for auxiliary contacts
● at 690 V / for combination switch + gG fuse / maximum permissible10 kA
Compliance with the substance restrictions according to RoHS directiveGiven
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value125 A
● for rated value of the current / at AC / in hot operating state / per pole12 W
number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
number of connectable NC contacts / for auxiliary contacts / attachable / maximum3
number of connectable NO contacts / for auxiliary contacts / attachable / maximum5
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-110 kA
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value75
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value100
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum104 kA2.s
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value600 V
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum104 kA2.s
General Product ApprovalConfirmationMiscellaneousGeneral Product ApprovalDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformitySpecial Test CertificateMiscellaneousotherEnvironmental ConfirmationsGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top