| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209470552 |
| UPC | Not available |
| ETIM | 4 |
| Depth | 221 mm |
| Notes | Sucessor:3KF1306-0MB11, different dimensions, some deviating technical values. |
| Width | 172 mm |
| Height | 100 mm |
| UNSPSC | 14 |
| eClass | 6 |
| version | Basic version without handle |
| Group Code | P360 |
| Design type | plug connector on the top |
| Fuse system | fuses according to BS 88 |
| Price Group | 12S |
| ● maximum | 55 °C |
| ● minimum | -25 °C |
| Metal Factor | LAO----- |
| Mounting type | clip-on |
| Product Group | 5853 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85362010 |
| Product family | Ordering Data Overview |
| Net Weight (kg) | 1,405 Kg |
| Operating power | |
| number of poles | 3 |
| type of voltage | AC/DC |
| Type of mounting | plug-in version |
| Country of origin | Germany |
| Operating voltage | |
| mounting position | any |
| ● safety switch | Yes |
| LKZ_FDB/ CatalogID | LV10.1 |
| PLM Effective Date | Product phase-out since: 31.08.2018 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| Packaging Dimension | 258,00 x 276,00 x 132,00 |
| Product Description | Switch disconnector with fuse in new design Iu=63 A, Ue = 690 V, 3-pole for BS88 fuse form A2/A3 basic version without 8UC6 handle and shaft with isolating contact strip for MCC |
| Product designation | Switch disconnector |
| Protection class IP | IP00 |
| Suitability for use | |
| Design of the product | With fuses and 3KM isolating contact strip |
| ● AC-21 A / at 400 V | 63 A |
| ● AC-21 A / at 500 V | 63 A |
| ● AC-21 B / at 400 V | 63 A |
| ● AC-21 B / at 500 V | 63 A |
| ● AC-22 A / at 400 V | 63 A |
| ● AC-22 A / at 500 V | 63 A |
| ● AC-22 B / at 400 V | 63 A |
| ● AC-22 B / at 500 V | 63 A |
| ● stranded / maximum | 35 mm² |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| ● at DC / rated value | 440 V |
| Interlockable (EF006281) | true |
| ● EMERGENCY OFF switch | Yes |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : N |
| Number of poles (EF001391) | 3 |
| Size of disconnecting link | Form A2/A3 |
| certificate of suitability | CE |
| Product feature / interlock | Yes |
| Standard lead time ex-works | 15 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| Number of switches (EF005586) | - |
| Device construction (EF008240) | Built-in device plug-in technique |
| Product Dimensions (W x L x H) | Not available |
| Motor drive optional (EF007386) | false |
| Operating current / rated value | 63 A |
| Continuous current / rated value | 63 A |
| Insulation voltage / rated value | 690 V |
| Type of connection, main circuit | flat connector bottom connection, M6 |
| Colour control element (EF007167) | Other |
| Design of the operating mechanism | manual operating mechanism |
| Motor drive integrated (EF006697) | false |
| Version as main switch (EF006981) | true |
| ● mounting type / rail mounting | Yes |
| Rated operating voltage (EF001435) | - |
| Type of control element (EF006976) | Other |
| Switching power at 400 V (EF009166) | - |
| Version as safety switch (EF006985) | true |
| Voltage release optional (EF007491) | false |
| Ambient temperature / during storage | |
| Article Number (Market Facing Number) | 3KM5030-1AG01 |
| Rated permanent current Iu (EF001389) | 63.0 |
| ● at AC / at 50/60 Hz / rated value | 690 V |
| Ambient temperature / during operation | |
| Degree of protection (NEMA) (EF011959) | - |
| Suitable for floor mounting (EF007243) | FALSE |
| Surge voltage resistance / rated value | 6 000 V |
| Version as reversing switch (EF009408) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● at AC-23 A / at 500 V / rated value | 30 000 W |
| Number of poles / for main current circuit | 3 |
| Operating current / at AC-21 / rated value | 63 A |
| Type of the driving mechanism / motor drive | No |
| ● reference code / acc. to DIN EN 61346-2 | Q |
| Max. rated operation voltage Ue AC (EF007355) | 690 |
| Suitable for front mounting 4-hole (EF007247) | false |
| Suitable for front mounting centre (EF007248) | false |
| Suitable for intermediate mounting (EF007264) | true |
| Number of CO contacts / for auxiliary contacts | 0 |
| Number of NC contacts / for auxiliary contacts | 0 |
| Number of NO contacts / for auxiliary contacts | 0 |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Degree of protection (IP), front side (EF003118) | IP00 |
| Rated operation power at AC-23, 400 V (EF007027) | 30.0 |
| Rated short-time withstand current lcw (EF007050) | - |
| Version as emergency stop installation (EF006959) | true |
| Version as maintenance-/service switch (EF006986) | true |
| Rated permanent current at AC-21, 400 V (EF009165) | - |
| Rated permanent current at AC-23, 400 V (EF011777) | 63 |
| Rated current Ie / maximum / in utilization category | |
| Conditioned rated short-circuit current Iq (EF001444) | - |
| ● at AC-23 A / at 400 V / at 50/60 Hz / rated value | 30 000 W |
| ● at AC-23 A / at 690 V / at 50/60 Hz / rated value | 40 000 W |
| Connectable conductor cross-section / for main contacts | |
| Suitable for distribution board installation (EF007262) | true |
| Type of electrical connection of main circuit (EF006819) | Other |
| ● Mounting type / front mounting with 4-hole attachment | No |
| ● Mounting type / front mounting with central attachment | No |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Conditional rated short-circuit current / in utilization category | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Compliance with the substance restrictions according to RoHS directive | Given |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole | 3 W |
| Let-through current / I2 t / maximum permissible / in utilization category / AC-22 B / at 400 V | 130 000 A²·s |
| Declaration of ConformityTest CertificatesShipping ApprovalotherSpecial Test CertificateMiscellaneous | Declaration of Conformity |
Technical specifications and performance data
Installation and operation guide