3KF1306-0MR11-8AA1 - 3KF1306-0MR11-8AA1 SIEMENS Switch disconnector with fuse 63A, size 2, 3-pole LV HRC-fuse Sz. 000 and 00 Fron..
In Stock Hot Product

3KF1306-0MR11-8AA1

3KF1306-0MR11-8AA1 SIEMENS Switch disconnector with fuse 63A, size 2, 3-pole LV HRC-fuse Sz. 000 and 00 Fron..

$0.00USD
3213 in stock
Key Specifications
:
EAN:4001869570150
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4001869570150
UPCNot available
ETIM5
depth145.5 mm
width144.5 mm
eClass6
height104 mm
I2t value
Group CodeP360
net weight1 200 g
fuse systemLV HRC fuse
● maximum22 N·m
● minimum15 N·m
Date5/5/2022
Metal FactorLAO-----
Miscellaneous
Product Group5379
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
Commodity Code85365080
Product familySENTRON 3KF Switch Disconnectors with Fuses
power loss [W]
Net Weight (kg)1,668 Kg
number of poles3
● main switchYes
● motor driveNo
design of handleWithout
fastening methodfloor mounting
product function
● on the frontIP20
Country of originChina
mounting positionany
size of fuse linkNH000, NH00
● rail mountingYes
● safety switchYes
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
product variations3KF SIVACON
Packaging Dimension190,00 x 210,00 x 150,00
Product DescriptionSwitch disconnector with fuse 63A, size 2, 3-pole LV HRC-fuse Sz. 000 and 00 Frontoperatingmechanism center Basic device without handle flat terminal on the rear specific SIVACON part number
operational current
protection class IPIP00
suitability for use
● fuse monitoringYes
overvoltage categoryIV
design of the product3KF switch disconnector with fuses
● for copper busbar1x (12 x 2 mm²)
direction of actuationfrom the front
● locking capabilityYes
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value63 A
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
● EMERGENCY OFF switchYes
● 4-hole front mountingNo
● at AC-23 A / at 440 V10 000
● at AC-23 A / at 690 V6 000
● at DC-23 A / at 440 V1 500
Export Control RegulationsAL : N / ECCN : N
product feature / sealableYes
size of disconnecting link00 and 000
Standard lead time ex-works12 Day/Days
Surcharge for Raw MaterialsNone
product feature / interlockNo
size of switch disconnector1
● at 35 °C / rated value63 A
● at 40 °C / rated value63 A
● at 45 °C / rated value63 A
● at 50 °C / rated value63 A
● at 55 °C / rated value63 A
● at 60 °C / rated value63 A
● at 65 °C / rated value63 A
● at 70 °C / rated value63 A
Package size unit of measureMM
product extension / optional
● maintenance/repair switchYes
design of the actuating elementwithout
operational current / rated value63 A
ambient temperature / during storage
product extension / auxiliary switchYes
● of the fuse / per fuse / maximum7.5 W
Article Number (Market Facing Number)3KF1306-0MR11-8AA1
● overvoltage protection monitoringNo
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
surge voltage resistance / rated value12 kV
electrical endurance (switching cycles)
● at 500 V / by gG fuse / rated value100 kA
● at 690 V / by gG fuse / rated value100 kA
● at AC-21 A / at 500 V / rated value63 A
● at AC-21 A / at 690 V / rated value63 A
● at DC-21 A / at 220 V / rated value63 A
● product component / voltage triggerNo
let-through current / with closed switch
operational current / at DC / rated value63 A
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
type of connectable conductor cross-sections
● product component / undervoltage releaseNo
tightening torque / with screw-type terminals
number of CO contacts / for auxiliary contacts4
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
● at DC-21 A / at 440 V / rated value / note63 A
● at DC-22 A / at 220 V / rated value / note63 A
● at DC-22 A / at 440 V / rated value / note63 A
● at DC-23 A / at 220 V / rated value / note63 A
● at DC-23 A / at 440 V / rated value / note63 A
● product function / phase failure monitoringNo
operating voltage / with current paths in series
● of the fuse / at 500 V / maximum permissible34 000 A²·s
● stranded / with lug / according to DIN 462341x (1 ... 35 mm²)
● stranded / with lug / according to DIN 462351x (1 ... 35 mm²)
operating voltage / at AC / rated value / maximum690 V
● of the aM fuse / at 690 V / maximum permissible55 000 A²·s
● of the gG fuse / at 690 V / maximum permissible55 000 A²·s
Region Specific PriceGroup / Headquarter Price Group12S / 1DL
mechanical service life (switching cycles) / typical15 000
● with degree of pollution 2 / at DC / rated value440 / 3
● with degree of pollution 3 / at DC / rated value440 / 3
operating power / at AC-23 A / at 500 V / rated value37 kW
● with closed switch / with cover or cable lug coverIP20
● with conventional rated thermal current / per pole1.7 W
number of connected CO contacts / for auxiliary contacts0
number of connected NC contacts / for auxiliary contacts0
number of connected NO contacts / for auxiliary contacts0
type of electrical connection / for main current circuitflat connector
● with conventional rated thermal current / per device5.1 W
arrangement of electrical connectors / for main current circuitRear
● product component / undervoltage release with leading contactNo
conditional short-circuit current / with line-side fuse protection
let-through current / of the fuse / at 500 V / maximum permissible11 800 A
● for combination switch + fuse / at 400 V / maximum permissible10 400 A
● for combination switch + fuse / at 500 V / maximum permissible10 400 A
type of connectable conductor cross-sections / for copper conductor
let-through current / of the aM fuse / at 690 V / maximum permissible11 500 A
let-through current / of the gG fuse / at 690 V / maximum permissible11 500 A
● at 690 V / for combination switch + aM fuse / maximum permissible11 200 A
● at 690 V / for combination switch + gG fuse / maximum permissible11 200 A
● with conventional rated thermal current / without fuse / per pole1.7 W
Compliance with the substance restrictions according to RoHS directiveSince: 24.01.2019
● with conventional rated thermal current / without fuse / per device5.1 W
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● with closed switch / for combination switch + fuse / at 400 V / maximum33 200 A²·s
● with closed switch / for combination switch + fuse / at 500 V / maximum33 200 A²·s
● for rated value of the current / at AC / in hot operating state / per pole1.7 W
● with closed switch / at 690 V / for combination switch + gG fuse / maximum40 700 A²·s
short-time withstand current (Icw) / at 690 V AC/440 V DC / limited to 1 s / rated value2.5 kA
type of connectable conductor cross-sections / for aluminum conductor / stranded / with lug1x (1 ... 35 mm²)
General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityotherMiscellaneousGeneral Product Approval
short-circuit current making capacity (Icm) / for switch disconnector / at 690 V AC/440 V DC / without fuse link / rated value / minimum3.55 kA

Product Description

Disconnector switch with fuse 63 A, size 1, 3 poles for fuse NH tam. 000 and 00 Central front drive base unit without lever rear flat connection, specific module SIVACON. Cancelations and returns limi
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide