3KF1306-0MB11 - 3KF1306-0MB11 SIEMENS Switch disconnector with fuse 63 A, Size 1, 3-pole for LV HRC fuse Sz. 000 Front opera..
In Stock Hot Product

3KF1306-0MB11

3KF1306-0MB11 SIEMENS Switch disconnector with fuse 63 A, Size 1, 3-pole for LV HRC fuse Sz. 000 Front opera..

$0.00USD
3747 in stock
Key Specifications
:
EAN:4001869535890
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4001869535890
UPCNot available
ETIM5
depth130.5 mm
width144.5 mm
eClass6
height122 mm
I2t value
● solid1x (1 ... 16 mm²)
Group CodeP360
net weight1 300 g
fuse systemLV HRC fuse
● maximum6.5 N·m
● minimum5 N·m
Metal FactorLAO-----
● stranded1x (6 ... 25 mm²)
Date5/15/2022
Product Group5379
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
Commodity Code85362010
Product familySENTRON 3KF Switch Disconnectors with Fuses
power loss [W]
Net Weight (kg)1,487 Kg
number of poles3
● main switchYes
● motor driveNo
design of handleWithout
fastening methodFloor mounting and snap-on mounting on 35 mm standard mounting rail
product function
● on the frontIP20
Country of originChina
mounting positionany
size of fuse linkNH000, NH00
● rail mountingYes
● safety switchYes
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
product variations3KF NH
Packaging Dimension190,00 x 150,00 x 135,00
Product DescriptionSwitch disconnector with fuse 63 A, Size 1, 3-pole for LV HRC fuse Sz. 000 Front operating mechanism center Basic unit without handle Box terminal
operational current
protection class IPIP20
suitability for use
● fuse monitoringYes
overvoltage categoryIV
design of the product3KF switch disconnector with fuses
direction of actuationfrom the front
● locking capabilityYes
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value63 A
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
Interlockable (EF006281)false
● EMERGENCY OFF switchYes
Declaration of ConformityMarine / Shipping
● 4-hole front mountingNo
● at AC-23 A / at 440 V10 000
● at AC-23 A / at 690 V6 000
● at DC-23 A / at 440 V1 500
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
product feature / sealableYes
size of disconnecting link00 and 000
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
product feature / interlockNo
size of switch disconnector1
● at 35 °C / rated value63 A
● at 40 °C / rated value63 A
● at 45 °C / rated value63 A
● at 50 °C / rated value63 A
● at 55 °C / rated value63 A
● at 60 °C / rated value63 A
● at 65 °C / rated value63 A
● at 70 °C / rated value63 A
Package size unit of measureMM
product extension / optional
Number of switches (EF005586)-
● maintenance/repair switchYes
Device construction (EF008240)Built-in device fixed built-in technique
Motor drive optional (EF007386)false
design of the actuating elementwithout
Colour control element (EF007167)Other
Motor drive integrated (EF006697)false
Version as main switch (EF006981)true
operational current / rated value63 A
Rated operating voltage (EF001435)-
Type of control element (EF006976)None
Switching power at 400 V (EF009166)30.0
Version as safety switch (EF006985)true
Voltage release optional (EF007491)false
ambient temperature / during storage
product extension / auxiliary switchYes
● of the fuse / per fuse / maximum7.5 W
Article Number (Market Facing Number)3KF1306-0MB11
Rated permanent current Iu (EF001389)63.0
● overvoltage protection monitoringNo
Degree of protection (NEMA) (EF011959)Other
Suitable for floor mounting (EF007243)FALSE
Version as reversing switch (EF009408)false
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
surge voltage resistance / rated value12 kV
electrical endurance (switching cycles)
● at 500 V / by gG fuse / rated value100 kA
● at 690 V / by gG fuse / rated value100 kA
● at AC-21 A / at 500 V / rated value63 A
● at AC-21 A / at 690 V / rated value63 A
● at DC-21 A / at 220 V / rated value63 A
● product component / voltage triggerNo
let-through current / with closed switch
operational current / at DC / rated value63 A
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
● product component / undervoltage releaseNo
Max. rated operation voltage Ue AC (EF007355)690
Suitable for front mounting 4-hole (EF007247)false
Suitable for front mounting centre (EF007248)false
Suitable for intermediate mounting (EF007264)true
tightening torque / with screw-type terminals
number of CO contacts / for auxiliary contacts4
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
● at DC-21 A / at 440 V / rated value / note63 A
● at DC-22 A / at 220 V / rated value / note63 A
● at DC-22 A / at 440 V / rated value / note63 A
● at DC-23 A / at 220 V / rated value / note63 A
● at DC-23 A / at 440 V / rated value / note63 A
● finely stranded / with core end processing1x (6 ... 25 mm²)
Rated operation power at AC-3, 400 V (EF001364)-
● product function / phase failure monitoringNo
Degree of protection (IP), front side (EF003118)IP20
Rated operation power at AC-23, 400 V (EF007027)30.0
operating voltage / with current paths in series
● of the fuse / at 500 V / maximum permissible34 000 A²·s
Rated short-time withstand current lcw (EF007050)2.5
Version as emergency stop installation (EF006959)true
Version as maintenance-/service switch (EF006986)true
operating voltage / at AC / rated value / maximum690 V
Rated permanent current at AC-21, 400 V (EF009165)63
Rated permanent current at AC-23, 400 V (EF011777)-
● of the aM fuse / at 690 V / maximum permissible55 000 A²·s
● of the gG fuse / at 690 V / maximum permissible55 000 A²·s
Region Specific PriceGroup / Headquarter Price Group12S / 1DL
mechanical service life (switching cycles) / typical15 000
● with degree of pollution 2 / at DC / rated value440 / 3
● with degree of pollution 3 / at DC / rated value440 / 3
Conditioned rated short-circuit current Iq (EF001444)-
operating power / at AC-23 A / at 500 V / rated value37 kW
● with closed switch / with cover or cable lug coverIP20
● with conventional rated thermal current / per pole1.7 W
Suitable for distribution board installation (EF007262)true
Type of electrical connection of main circuit (EF006819)Frame clamp
number of connected CO contacts / for auxiliary contacts0
number of connected NC contacts / for auxiliary contacts0
number of connected NO contacts / for auxiliary contacts0
type of electrical connection / for main current circuitbox terminal
● with conventional rated thermal current / per device5.1 W
Number of auxiliary contacts as change-over contact (EF003531)4
arrangement of electrical connectors / for main current circuitTop and bottom
Number of auxiliary contacts as normally open contact (EF001376)0
● product component / undervoltage release with leading contactNo
Number of auxiliary contacts as normally closed contact (EF001377)0
conditional short-circuit current / with line-side fuse protection
let-through current / of the fuse / at 500 V / maximum permissible11 800 A
● for combination switch + fuse / at 400 V / maximum permissible10 400 A
● for combination switch + fuse / at 500 V / maximum permissible10 400 A
type of connectable conductor cross-sections / for copper conductor
type of connectable conductor cross-sections / with flexible busbar2x (0.8 x 9 mm²)
let-through current / of the aM fuse / at 690 V / maximum permissible11 500 A
let-through current / of the gG fuse / at 690 V / maximum permissible11 500 A
● at 690 V / for combination switch + aM fuse / maximum permissible11 200 A
● at 690 V / for combination switch + gG fuse / maximum permissible11 200 A
● with conventional rated thermal current / without fuse / per pole1.7 W
Compliance with the substance restrictions according to RoHS directiveSince: 31.01.2016
● with conventional rated thermal current / without fuse / per device5.1 W
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● with closed switch / for combination switch + fuse / at 400 V / maximum33 200 A²·s
● with closed switch / for combination switch + fuse / at 500 V / maximum33 200 A²·s
● for rated value of the current / at AC / in hot operating state / per pole1.7 W
● with closed switch / at 690 V / for combination switch + gG fuse / maximum40 700 A²·s
short-time withstand current (Icw) / at 690 V AC/440 V DC / limited to 1 s / rated value2.5 kA
short-circuit current making capacity (Icm) / for switch disconnector / at 690 V AC/440 V DC / without fuse link / rated value / minimum3.55 kA
General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityMarine / ShippingotherMiscellaneousGeneral Product Approval

Product Description

INTERR.-DISCONNECTOR C / FUSES 63A, SIZE 1, 3 POLES FOR FUSES NH TAM. 000 ACCTO. FRONT IN CENTER BASE UNIT WITHOUT HANDLE BOX TERMINALS. Cancelations and returns limited. Consult conditions.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top