Service time: Monday to Friday 9:00-18:00
3KD3840-0PE10-0 - 3KD3840-0PE10-0 SIEMENS Switch disconnector 250 A, Size 3, 4-pole Front operating mechanism left Basic unit ..
In Stock Hot Product

3KD3840-0PE10-0

3KD3840-0PE10-0 SIEMENS Switch disconnector 250 A, Size 3, 4-pole Front operating mechanism left Basic unit ..

$0.00USD
3694 in stock
Key Specifications
:Confirmation
EAN:4001869472744
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4001869472744
UPCNot available
ETIM5
depth93.5 mm
width234 mm
UNSPSC15
eClass6
height164 mm
I2t value
Group CodeP360
net weight3 540 g
● maximum70 °C
● minimum-25 °C
Date5/6/2022
Metal FactorLOA-----
Product Group5378
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85365080
Product familyBasic Devices
power loss [W]
type of devicefixed mounting
Net Weight (kg)3,540 Kg
number of poles4
operating power
● main switchYes
● motor driveNo
● rated value1 000 V
fastening methodscrew fixing
● on the frontIP00
Country of originChina
mounting positionany
product component
● rail mountingNo
● safety switchYes
LKZ_FDB/ CatalogIDLV10.1
Packaging Quantity1
insulation voltage
product brand nameSENTRON
● trip indicatorNo
Packaging Dimension190,00 x 264,00 x 121,00
Product DescriptionSwitch disconnector 250 A, Size 3, 4-pole Front operating mechanism left Basic unit without handle flat terminal
degree of pollution3
operational current
product designation3KD switch disconnector
protection class IPIP00
suitability for use
● voltage triggerNo
overvoltage categoryIV
design of the productSwitch
● for copper busbar'1 x (30 x 10 mm²)
Product Lifecycle (PLM)PM300:Active Product
● at AC / rated value250 A
● stranded / with lug1x (25 ... 240 mm²), 2x (25 ... 120 mm²)
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
Interlockable (EF006281)false
● EMERGENCY OFF switchYes
● undervoltage releaseNo
Declaration of ConformityMarine / Shipping
● 4-hole front mountingNo
● at AC-23 A / at 690 V1 000
● at DC-23 A / at 440 V1 000
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)4
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
product feature / interlockNo
size of switch disconnector3
● at 35 °C / rated value250 A
● at 40 °C / rated value250 A
● at 45 °C / rated value250 A
● at 50 °C / rated value250 A
● at 55 °C / rated value250 A
● at 60 °C / rated value250 A
● at 65 °C / rated value250 A
● at 70 °C / rated value250 A
Package size unit of measureMM
product extension / optional
Number of switches (EF005586)-
type of the driving mechanismFront operating mechanism
● maintenance/repair switchYes
Device construction (EF008240)Built-in device fixed built-in technique
Motor drive optional (EF007386)false
design of the actuating elementWithout handle
Colour control element (EF007167)Other
Motor drive integrated (EF006697)false
Version as main switch (EF006981)true
operational current / rated value250 A
Rated operating voltage (EF001435)-
Type of control element (EF006976)None
Switching power at 400 V (EF009166)132.0
Version as safety switch (EF006985)true
Voltage release optional (EF007491)false
ambient temperature / during storage
product extension / auxiliary switchYes
● at AC-20 A / at 1000 V / maximum250 A
● at AC-22 A / at 1000 V / maximum250 A
Article Number (Market Facing Number)3KD3840-0PE10-0
Rated permanent current Iu (EF001389)250.0
Degree of protection (NEMA) (EF011959)-
Suitable for floor mounting (EF007243)FALSE
Version as reversing switch (EF009408)false
WEEE (2012/19/EU) Take-Back ObligationYes
ambient temperature / during operation
surge voltage resistance / rated value12 kV
electrical endurance (switching cycles)
● at 500 V / by gG fuse / rated value100 kA
● at 690 V / by gG fuse / rated value100 kA
● at AC-21 A / at 500 V / rated value250 A
● at AC-21 A / at 690 V / rated value250 A
● at AC-22 A / at 400 V / rated value250 A
● at AC-22 A / at 500 V / rated value250 A
● at AC-22 A / at 690 V / rated value250 A
● at AC-23 A / at 400 V / rated value250 A
● at AC-23 A / at 500 V / rated value250 A
● at AC-23 A / at 690 V / rated value250 A
operational current / at DC / rated value250 A
● front mounting with central attachmentNo
type of the driving mechanism / motor driveNo
position / of the switch operating mechanismat the left end
type of connectable conductor cross-sections
Max. rated operation voltage Ue AC (EF007355)690
Suitable for front mounting 4-hole (EF007247)false
Suitable for front mounting centre (EF007248)false
Suitable for intermediate mounting (EF007264)false
● undervoltage release with leading contactNo
● without fuse link / rated value / minimum36 kA
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts6
number of NO contacts / for auxiliary contacts6
Rated operation power at AC-3, 400 V (EF001364)-
Degree of protection (IP), front side (EF003118)IP00
Rated operation power at AC-23, 400 V (EF007027)132.0
operating voltage / with current paths in series
● of the fuse / at 500 V / maximum permissible780 005 A²·s
● stranded / with lug / according to DIN 462351x (16 ... 185 mm²), 2x (16 ...150 mm²)
Rated short-time withstand current lcw (EF007050)-
Version as emergency stop installation (EF006959)true
Version as maintenance-/service switch (EF006986)true
Rated permanent current at AC-21, 400 V (EF009165)250
Rated permanent current at AC-23, 400 V (EF011777)-
● of the gG fuse / at 690 V / maximum permissible525 005 A²·s
Region Specific PriceGroup / Headquarter Price Group12S / 1CL
mechanical service life (switching cycles) / typical15 000
● with degree of pollution 2 / at DC / rated value440 V / 3
● with degree of pollution 3 / at DC / rated value440 V / 3
Conditioned rated short-circuit current Iq (EF001444)-
● with closed switch / with cover or cable lug coverIP20
● with conventional rated thermal current / per pole6 W
Suitable for distribution board installation (EF007262)false
Type of electrical connection of main circuit (EF006819)Other
number of connected CO contacts / for auxiliary contacts0
number of connected NC contacts / for auxiliary contacts0
number of connected NO contacts / for auxiliary contacts0
type of electrical connection / for main current circuitflat connector
● with conventional rated thermal current / per device24 W
● at 415 V / by molded case circuit breaker / rated value65 kA
● at DC 440 V / without fuse link / rated value / minimum36 kA
● at 1000 V AC / without fuse link / rated value / minimum36 kA
● of the gG/aM SITOR fuse / at 1000 V / maximum permissible260 000 A²·s
Number of auxiliary contacts as change-over contact (EF003531)0
continuous current / of upstream fuse / at 1000 V / rated value500 A
Number of auxiliary contacts as normally open contact (EF001376)6
Number of auxiliary contacts as normally closed contact (EF001377)6
conditional short-circuit current / with line-side fuse protection
let-through current / of the fuse / at 500 V / maximum permissible54 800 A
type of connectable conductor cross-sections / for copper conductor
let-through current / of the gG fuse / at 690 V / maximum permissible45 200 A
short-circuit current making capacity (Icm) / for switch disconnector
type of connectable conductor cross-sections / for aluminum conductor
Compliance with the substance restrictions according to RoHS directiveSince: 24.11.2009
● of the molded case circuit breaker / at 415 V / maximum permissible4 750 000 A²·s
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
continuous current / of upstream fuse / at 500 V and 690 V / rated value500 A
● for rated value of the current / at AC / in hot operating state / per pole6 W
let-through current / of the gG/aM SITOR fuse / at 1000 V / maximum permissible21 500 A
continuous current / of upstream molded case circuit breaker / at 415 V / rated value630 A
● with closed switch / at 1000 V / for combination switch +gG/aM SITOR fuse / maximum239 650 A²·s
display version / for switch position indicator door-coupling rotary operating mechanismON-OFF
let-through current / of the molded case circuit breaker / at 415 V / maximum permissible43 500 A
short-time withstand current (Icw) / at 1000 V AC/440 V DC / limited to 1 s / rated value13 kA
overvoltage in percent / relative to the operating voltage / at AC / at 400, 500, 690 V / at 50/60 Hz10 %
General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityMarine / ShippingotherMiscellaneousGeneral Product Approval

Product Description

SWITCH-DISCONNECTOR 250A, SIZE 3, 4 POLES ACCTO. FRONT TO LEFT. BASE UNIT WITHOUT LEVER FLAT CONNECTION
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top