| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4001869472232 |
| UPC | Not available |
| ETIM | 7 |
| depth | 97 mm |
| width | 148 mm |
| UNSPSC | 15 |
| eClass | 12 |
| height | 126 mm |
| I2t value | |
| ● solid | 1x (2.5 ... 16 mm²) |
| Group Code | P360 |
| net weight | 1 493 g |
| ● maximum | 70 °C |
| ● minimum | -25 °C |
| Metal Factor | LOA----- |
| ● stranded | 1x (10 ... 70 mm²) |
| Date8/25/2023 | Subject to change without notice© Copyright Siemens 2023 |
| Product Group | 5378 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85365080 |
| Product family | Basic Devices |
| last modified: | 9/23/2021 |
| power loss [W] | |
| type of device | fixed mounting |
| Net Weight (kg) | 1,442 Kg |
| number of poles | 4 |
| operating power | |
| ● main switch | Yes |
| ● motor drive | No |
| ● rated value | 1 000 V |
| fastening method | Screw fixing and standard rail mounting 35 mm |
| ● on the front | IP20 |
| Country of origin | China |
| mounting position | any |
| product component | |
| ● rail mounting | Yes |
| ● safety switch | Yes |
| LKZ_FDB/ CatalogID | LV10.1 |
| Packaging Quantity | 1 |
| insulation voltage | |
| product brand name | SENTRON |
| ● trip indicator | No |
| Packaging Dimension | 148,00 x 155,00 x 102,00 |
| Product Description | Switch disconnector 100 A, Size 2, 4-pole Front operating mechanism left Complete unit with direct operating mechanism gray Box terminal |
| degree of pollution | 3 |
| product designation | 3KD switch disconnector |
| protection class IP | IP20 |
| suitability for use | |
| ● voltage trigger | No |
| overvoltage category | III |
| design of the product | Switch |
| ● for copper busbar | '1 x (3 x 14 mm²) |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AC-23 A at 690 V | 1 500 |
| ● switch disconnector | Yes |
| General Product Approval | Declaration of Conformity |
| Interlockable (EF006281) | true |
| ● EMERGENCY OFF switch | No |
| ● undervoltage release | No |
| Declaration of Conformity | Marine / Shipping |
| ● 4-hole front mounting | No |
| Export Control Regulations | AL : N / ECCN : N |
| Number of poles (EF001391) | 4 |
| product extension optional | |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| size of switch disconnector | 2 |
| Package size unit of measure | MM |
| Number of switches (EF005586) | - |
| type of the driving mechanism | Front operating mechanism |
| ● maintenance/repair switch | Yes |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Motor drive optional (EF007386) | false |
| design of the actuating element | Long rotary knob |
| operational current rated value | 100 A |
| Colour control element (EF007167) | Grey |
| Motor drive integrated (EF006697) | false |
| Version as main switch (EF006981) | true |
| Rated operating voltage (EF001435) | - |
| Type of control element (EF006976) | Long turning handle |
| ambient temperature during storage | |
| product extension auxiliary switch | Yes |
| Switching power at 400 V (EF009166) | 55.0 |
| Version as safety switch (EF006985) | true |
| Voltage release optional (EF007491) | false |
| ● at 500 V by gG fuse rated value | 100 kA |
| ● at 690 V by gG fuse rated value | 100 kA |
| ● at AC-23 A at 500 V rated value | 55 kW |
| ambient temperature during operation | |
| surge voltage resistance rated value | 8 kV |
| Article Number (Market Facing Number) | 3KD3042-2NE10-0 |
| Rated permanent current Iu (EF001389) | 100.0 |
| Degree of protection (NEMA) (EF011959) | - |
| Suitable for floor mounting (EF007243) | FALSE |
| Version as reversing switch (EF009408) | false |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| electrical endurance (operating cycles) | |
| reference code according to IEC 81346-2 | Q |
| type of the driving mechanism motor drive | No |
| ● without fuse link rated value minimum | 12 kA |
| position of the switch operating mechanism | at the left end |
| ● front mounting with central attachment | No |
| number of CO contacts for auxiliary contacts | 4 |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 0 |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (2.5 ... 70 mm²) |
| ● of the fuse at 500 V maximum permissible | 223 005 A²·s |
| Max. rated operation voltage Ue AC (EF007355) | 690 |
| Suitable for front mounting 4-hole (EF007247) | false |
| Suitable for front mounting centre (EF007248) | false |
| Suitable for intermediate mounting (EF007264) | true |
| ● undervoltage release with leading contact | No |
| operating voltage with current paths in series | |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| ● of the gG fuse at 690 V maximum permissible | 226 005 A²·s |
| Degree of protection (IP), front side (EF003118) | IP20 |
| Rated operation power at AC-23, 400 V (EF007027) | 55.0 |
| ● with degree of pollution 2 at DC rated value | 440 V / 3 |
| ● with degree of pollution 3 at DC rated value | 440 V / 3 |
| Rated short-time withstand current lcw (EF007050) | - |
| Version as emergency stop installation (EF006959) | false |
| Version as maintenance-/service switch (EF006986) | true |
| Rated permanent current at AC-21, 400 V (EF009165) | 100 |
| Rated permanent current at AC-23, 400 V (EF011777) | - |
| mechanical service life (operating cycles) typical | 15 000 |
| Region Specific PriceGroup / Headquarter Price Group | 12S / 1CL |
| ● with closed switch with cover or cable lug cover | IP20 |
| ● with conventional rated thermal current per pole | 1.8 W |
| Conditioned rated short-circuit current Iq (EF001444) | - |
| ● at 400 V AC without fuse link rated value minimum | 30 kA |
| ● at DC 440 V without fuse link rated value minimum | 12 kA |
| number of connected CO contacts for auxiliary contacts | 0 |
| number of connected NC contacts for auxiliary contacts | 0 |
| number of connected NO contacts for auxiliary contacts | 0 |
| type of electrical connection for main current circuit | box terminal |
| ● at 1000 V AC without fuse link rated value minimum | 12 kA |
| ● with conventional rated thermal current per device | 7.2 W |
| Suitable for distribution board installation (EF007262) | true |
| ● at 415 V by molded case circuit breaker rated value | 65 kA |
| Type of electrical connection of main circuit (EF006819) | Frame clamp |
| ● of the gG/aM SITOR fuse at 1000 V maximum permissible | 48 000 A²·s |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| display version for switch position indicator manual operation | ON-OFF-TEST |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| conditional short-circuit current with line-side fuse protection | |
| type of connectable conductor cross-sections for copper conductor | |
| type of connectable conductor cross-sections with flexible busbar | 3x (0.8x14 mm²) |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| short-circuit current making capacity (Icm) for switch disconnector | |
| ● of the molded case circuit breaker at 415 V maximum permissible | 560 000 A²·s |
| Compliance with the substance restrictions according to RoHS directive | Since: 24.11.2009 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| ● for rated value of the current at AC in hot operating state per pole | 1.8 W |
| ● with closed switch at 1000 V for combination switch +gG/aM SITOR fuse maximum | 19 815 A²·s |
| short-time withstand current (Icw) at 1000 V AC/440 V DC limited to 1 s rated value | 4 kA |
| overvoltage in percent relative to the operating voltage at AC at 400, 500, 690 V at 50/60 Hz | 10 % |
| General Product ApprovalDeclaration of ConformityConfirmationMiscellaneousDeclaration of ConformityMarine / ShippingotherEnvironmentConfirmationMiscellaneousEnvironmental Confirmations | General Product Approval |
Technical specifications and performance data
Installation and operation guide