| Parameter | Value |
|---|---|
| Miscellaneous | |
| EAN | 4001869562490 |
| UPC | Not available |
| ETIM | 5 |
| depth | 43.3 mm |
| width | 144 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 144 mm |
| Group Code | P360 |
| net weight | 600 g |
| ● maximum | 70 °C |
| ● minimum | -30 °C |
| Confirmation | |
| Date5/5/2022 | |
| Metal Factor | None |
| Product Group | 5380 |
| Product class | D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer) |
| Quantity Unit | 1 Piece |
| ● rear side | IP20 |
| Commodity Code | 85389091 |
| Product family | SENTRON Transfer Control Devices |
| signal voltage | |
| Net Weight (kg) | 0,647 Kg |
| number of slots | 2 |
| input delay time | 0.05 s |
| ● on the front | IP40 |
| Country of origin | Italy |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| Packaging Dimension | 150,00 x 183,00 x 127,00 |
| Product Description | SENTRON 3KC ATC6300; LCD; 144x144 mm; Transfer control device for control of MCCB, ACB, LBS; for load transfer between main and standby power supply Control panel instrument; Un 100...240 V AC 50/60 Hz, 110...250 V DC; Un 12...24 V DC Rated voltage Ue: 100...480 V AC 50/60 Hz; screw terminal connection Expandable by maximum 2 additional modules |
| product designation | Accessories for transfer switching equipment |
| protection class IP | |
| ● at AC / maximum | 264 V |
| ● at AC / minimum | 90 V |
| ● at DC / maximum | 300 V |
| ● at DC / minimum | 93.5 V |
| overvoltage category | 3 |
| ● at AC / at 240 V | 3.8 W |
| design of the product | 3KC ATC6300 |
| operating temperature | |
| ● at 12 V / maximum | 3.2 W |
| ● at 24 V / maximum | 2.9 W |
| ● final rated value | 24 V |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● initial rated value | 12 V |
| General Product Approval | EMC |
| number of digital inputs | 6 |
| Declaration of Conformity | other |
| Export Control Regulations | AL : N / ECCN : N |
| number of monitored phases | 3 |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| type of electrical connection | Removable/plug-in |
| ● at AC / final rated value | 240 V |
| ● at DC / final rated value | 250 V |
| ● at DC / at 250 V / maximum | 3.6 W |
| ● at AC / initial rated value | 100 V |
| ● at DC / initial rated value | 110 V |
| operating frequency / rated value | |
| ● design of the switching input | Negative |
| connectable conductor cross-section | |
| power loss [W] / at DC power supply | |
| supply voltage / at DC power supply | |
| ● at DC-1 / at 30 V / rated value | 8 A |
| ambient temperature / during storage | |
| ● at AC-1 / at 250 V / rated value | 8 A |
| Article Number (Market Facing Number) | 3KC9000-8TL40 |
| consumed current / at DC power supply | |
| output current / at the relay outputs | |
| ● at AC-15 / at 250 V / rated value | 1.5 A |
| ● with 1 expansion module / maximum | 180 ms |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● with 2 expansion modules / maximum | 120 ms |
| Type of accessory/spare part (EF000215) | - |
| product feature / of enclosure material | Polycarbonate |
| switchover time / of the control device | 50 ms |
| ● without expansion modules / maximum | 250 ms |
| reference code / according to EN 61346-2 | K |
| ● for signal <0> / at DC / rated value | 2 V |
| ● for signal <1> / at DC / rated value | 3.4 V |
| power loss [W] / at auxiliary power supply | |
| type of contact rating / according to NEMA | B300 |
| number of CO contacts / for auxiliary contacts | 1 |
| number of NC contacts / for auxiliary contacts | 0 |
| number of NO contacts / for auxiliary contacts | 6 |
| supply voltage / of the auxiliary power supply | |
| operating period / without auxiliary power supply | 300 s |
| Region Specific PriceGroup / Headquarter Price Group | 14N / 1CL |
| installation depth / with expansion module / maximum | 73 mm |
| tightening torque / with screw-type terminals / maximum | 0.56 N·m |
| AWG number / as coded connectable conductor cross section | |
| connectable conductor cross-section / according to UL 508 | |
| number of outputs / as contact-affected switching element | 7 |
| input current / at digital input / with signal <0> / maximum | 8 mA |
| insulation voltage (Ui) / of the relay outputs / rated value | 250 V |
| electrical endurance (switching cycles) / of the relay outputs | 100 000 |
| mechanical service life (switching cycles) / of the relay outputs | 10 000 000 |
| tightening torque [lbf·in] / with screw-type terminals / maximum | 5 lbf·in |
| output voltage / at the relay outputs / at AC / maximum rated value | 250 V |
| product component / of the hardware real time clock / backup battery | Yes |
| impulse withstand voltage (Uimp) / of the relay outputs / rated value | 4 000 V |
| power frequency withstand voltage / at auxiliary power supply / at AC | 3 000 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2017 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| insulation voltage (Ui) / at auxiliary power supply / at AC / rated value | 250 V |
| interference immunity duration / against voltage dip/sag / at AC / at 220 V | |
| AWG number / as coded connectable conductor cross section / according to UL 508 | |
| apparent power consumption / at auxiliary power supply / at AC / at 240 V / maximum | 9.5 VA |
| impulse withstand voltage (Uimp) / of the auxiliary power supply / at AC / rated value | 6 000 V |
| switching capacity current / at the relay outputs / at DC / at 30 V / according to UL 508 | 1 A |
| General Product ApprovalEMCDeclaration of ConformityConfirmationMiscellaneousUK Declaration of ConformityDeclaration of ConformityotherMiscellaneous | General Product Approval |
Technical specifications and performance data
Installation and operation guide