Key Specifications
:Value
EAN:4001869527475
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4001869527475
UPCNot available
ETIM5
Depth292 mm
Width328 mm
Height160 mm
UNSPSC15
eClass6
I2t value
Group CodeP360
net weight6 600 g
Price Group12S
● maximum332 V
● minimum166 V
Metal FactorNone
Relay design1 relay: 1NO, 2A 250 VAC or 2A 24 VDC.
Mounting typescrew fixing
Product Group5380
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
Commodity Code85365080
Power loss [W]
Product familyBasic Devices
Type of devicefixed mounting
Net Weight (kg)9,060 Kg
Operating power
number of poles3
● Main switchYes
● motor driveNo
● rated value1 000 V
Design of handleHandle
Input delay time0.046 s
Country of originTunisia
Operating current
Operating voltage
● safety switchNo
Continuous current
Insulation voltage
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
Degree of pollution3
Packaging Dimension360,00 x 470,00 x 360,00
Product DescriptionSENTRON, transfer switching equipment 3KC, remotely operated, RTSE, 3-pole, Iu: 250 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 200 A, Ie at AC-23 A at 690 V: 125 A, screw mounting, motorized operating mechanism, at the right end, long handle, busbar connection
Product designation3KC transfer switching equipment
Protection class IPIP00
Suitability for use
● Voltage triggerNo
overvoltage categoryIV
Design of the productremote-controlled
● for copper busbar1x32x5
Supply voltage / at AC
Product Lifecycle (PLM)PM300:Active Product
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
Interlockable (EF006281)true
Pulse duration / minimum0.06 s
number of digital inputs5
● EMERGENCY OFF switchNo
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
Product feature / interlockYes
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
● at 40 °C / rated value250 A
● at 50 °C / rated value250 A
● at 60 °C / rated value250 A
● at 70 °C / rated value250 A
Package size unit of measureMM
Product extension / optional
Design of the switching inputConnected with control terminal
Number of switches (EF005586)-
Type of the driving mechanismmotorized operating mechanism
● maintenance/repair switchYes
Device construction (EF008240)Built-in device fixed built-in technique
Product Dimensions (W x L x H)Not available
Motor drive optional (EF007386)false
Operating current / rated value250 A
Colour control element (EF007167)Black
Design of the operating mechanismLong rotary knob
Motor drive integrated (EF006697)true
Operating frequency / rated value
Version as main switch (EF006981)true
● mounting type / rail mountingNo
Rated operating voltage (EF001435)['166.0', '332.0']
Type of control element (EF006976)Long turning handle
● at AC / at 230 V / Rated value0.5 A
Switching power at 400 V (EF009166)-
Version as safety switch (EF006985)false
Voltage release optional (EF007491)false
Ambient temperature / during storage
Product extension / Auxiliary switchYes
Article Number (Market Facing Number)3KC4338-0CA21-0AA3
Rated permanent current Iu (EF001389)250.0
● at AC / at 50/60 Hz / rated value415 V
● at AC-21 / at 500 V / rated value250 A
● at AC-21 / at 690 V / rated value200 A
Ambient temperature / during operation
Degree of protection (NEMA) (EF011959)Other
Suitable for floor mounting (EF007243)FALSE
Version as reversing switch (EF009408)-
WEEE (2012/19/EU) Take-Back ObligationYes
● protection class IP / on the frontIP00
Operating current / at AC / rated value250 A
Operating current / at DC / rated value250 A
● at 415 V / by gG fuse / rated value50 kA
● at AC-21 A / at 415 V / rated value250 A
● at AC-21 B / at 415 V / rated value250 A
● at AC-21 B / at 500 V / rated value250 A
● at AC-21 B / at 690 V / rated value200 A
● at AC-22 A / at 415 V / rated value250 A
● at AC-22 A / at 500 V / rated value200 A
● at AC-22 A / at 690 V / rated value160 A
● at AC-22 B / at 415 V / rated value250 A
● at AC-22 B / at 500 V / rated value250 A
● at AC-22 B / at 690 V / rated value160 A
● at AC-23 A / at 415 V / rated value200 A
● at AC-23 A / at 500 V / rated value200 A
● at AC-23 A / at 690 V / rated value125 A
● at AC-23 B / at 415 V / rated value200 A
● at AC-23 B / at 690 V / rated value125 A
● at AC-31 B / at 415 V / rated value250 A
● at AC-32 B / at 415 V / rated value200 A
● at AC-33 B / at 415 V / rated value200 A
● at DC-21 A / at 220 V / rated value250 A
● at DC-21 A / at 440 V / rated value200 A
● at DC-22 A / at 220 V / rated value250 A
● at DC-22 A / at 440 V / rated value200 A
● at DC-23 A / at 220 V / rated value200 A
● at DC-23 A / at 440 V / rated value200 A
let-through current / with closed switch
● at AC-33 iB / at 415 V / rated value250 A
Type of the driving mechanism / motor driveYes
● Reference code / acc. to DIN EN 81346-2Q
● reference code / acc. to DIN EN 61346-2Q
Position / of the switch operating mechanismat the right end
Type of connectable conductor cross-sections
Max. rated operation voltage Ue AC (EF007355)415
Suitable for front mounting 4-hole (EF007247)false
Suitable for front mounting centre (EF007248)false
Suitable for intermediate mounting (EF007264)false
Number of CO contacts / for auxiliary contacts4
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Rated operation power at AC-3, 400 V (EF001364)-
Degree of protection (IP), front side (EF003118)IP00
Rated operation power at AC-23, 400 V (EF007027)-
● of the fuse / at 415 V / maximum permissible200 000 A²·s
Rated short-time withstand current lcw (EF007050)-
Version as emergency stop installation (EF006959)false
Version as maintenance-/service switch (EF006986)true
Operating current / of upstream fuse / rated value250 A
Rated permanent current at AC-21, 400 V (EF009165)250
Rated permanent current at AC-23, 400 V (EF011777)-
● of the gG fuse / at 690 V / maximum permissible700 000 A²·s
● with degree of pollution 3 / at DC / rated value1 000 V
Conditioned rated short-circuit current Iq (EF001444)-
● at AC-23 A / at 690 V / at 50/60 Hz / rated value110 kW
● with conventional rated thermal current / per pole5.9 W
Suitable for distribution board installation (EF007262)false
Number of connected CO contacts / for auxiliary contacts0
Number of connected NC contacts / for auxiliary contacts0
Number of connected NO contacts / for auxiliary contacts3
Type of electrical connection of main circuit (EF006819)Rail connection
● with conventional rated thermal current / per device17.7 W
● Mounting type / front mounting with 4-hole attachmentNo
● Mounting type / front mounting with central attachmentNo
Input current / at digital input / with signal <0> / maximum1 mA
● Type of electrical connection / for main current circuitbusbar connection
● at 690 V / by gG fuse / acc. to IEC 60947-3 / rated value50 kA
● type of electrical connection / of the inputs and outputsRemovable/insertable
General Product ApprovalDeclaration of ConformityMiscellaneousGeneral Product Approval
Number of auxiliary contacts as change-over contact (EF003531)4
● at 415 V / by gG fuse / acc. to IEC 60947-6-1 / rated value50 kA
Display version / for switch position indicator manual operationI - O - II
Number of auxiliary contacts as normally open contact (EF001376)0
Conditional short-circuit current / with line-side fuse protection
Number of auxiliary contacts as normally closed contact (EF001377)0
Short-circuit current making capacity (Icm) / for switch disconnector
let-through current / of the gG fuse / at 690 V / maximum permissible22 000 A
● at 690 V / for combination switch + gG fuse / maximum permissible25 050 A
Compliance with the substance restrictions according to RoHS directiveSince: 31.07.2015
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● Protection class IP / with closed switch / with cover or cable lug coverIP20
● for rated value of the current / at AC / in hot operating state / per pole5.9 W
● with closed switch / at 690 V / for combination switch + gG fuse / maximum724 500 A²·s
● at AC 690 V / without fuse link / acc. to IEC 60947-3 / rated value / minimum22 kA
Mechanical service life (switching cycles) / for function sequence O-I-O / typical7 000
● at AC 415 V / without fuse link / acc. to IEC 60947-6-1 / rated value / minimum17 kA

Product Description

RTSE RTSE TRANSFER SWITCH, 250A, 3 POLES FRONT ACCONAMIENTO BASE UNIT WITH POWER HANDLE 230V AC FLAT CONNECTION. Cancelations and returns limited. Consult conditions.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top