Key Specifications
:Value
EAN:4001869537481
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4001869537481
UPCNot available
ETIM5
Depth84.5 mm
Width309.6 mm
Height126 mm
UNSPSC15
eClass6
I2t value
● solid1x (2.5 ... 16 mm²)
Group CodeP360
net weight2 650 g
Price Group12S
● maximum70 °C
● minimum-25 °C
Metal FactorNone
● stranded1x (10 ... 70 mm²)
Mounting typeScrew fixing and standard rail mounting 35 mm
Product Group5380
Product classB: return restricted, please contact your Siemens partner/contact
Quantity Unit1 Piece
Commodity Code85365080
Power loss [W]
Product familyBasic Devices
Type of devicefixed mounting
Net Weight (kg)2,798 Kg
Operating power
number of poles4
● Main switchYes
● motor driveNo
● rated value1 000 V
Design of handlewithout
Country of originChina
Operating current
Operating voltage
mounting positionany
● safety switchYes
Continuous current
Insulation voltage
LKZ_FDB/ CatalogIDLV10
Packaging Quantity1
product brand nameSENTRON
Degree of pollution3
Packaging Dimension126,00 x 310,00 x 85,00
Product DescriptionSENTRON, Transfer switching equipment 3KC, manually operated, MTSE, size: 2, 4-pole, Iu: 160 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 160 A, Ie at AC-23 A at 690 V: 125 A, screw and standard mounting rail on 35 mm, front operating mechanism, central, without handle, box terminal
Product designation3KC transfer switching equipment
Protection class IPIP20
Suitability for use
● Voltage triggerNo
overvoltage categoryIII
Design of the productmanually operated
● for copper busbar1x (3x14 mm²)
Product Lifecycle (PLM)PM300:Active Product
● switch disconnectorYes
General Product ApprovalDeclaration of Conformity
Interlockable (EF006281)false
● EMERGENCY OFF switchYes
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)4
Product feature / interlockNo
Size of switch disconnector2
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
● at 40 °C / rated value160 A
● at 45 °C / rated value160 A
● at 50 °C / rated value160 A
● at 55 °C / rated value160 A
● at 60 °C / rated value160 A
● at 65 °C / rated value160 A
● at 70 °C / rated value160 A
Package size unit of measureMM
Product extension / optional
Number of switches (EF005586)-
Type of the driving mechanismFront operating mechanism
● maintenance/repair switchYes
Device construction (EF008240)Built-in device fixed built-in technique
Product Dimensions (W x L x H)Not available
Motor drive optional (EF007386)false
Operating current / rated value160 A
Colour control element (EF007167)-
Design of the operating mechanismWithout handle
Motor drive integrated (EF006697)false
Version as main switch (EF006981)true
● mounting type / rail mountingYes
Rated operating voltage (EF001435)-
Type of control element (EF006976)None
Switching power at 400 V (EF009166)-
Version as safety switch (EF006985)true
Voltage release optional (EF007491)false
Ambient temperature / during storage
Product extension / Auxiliary switchYes
Article Number (Market Facing Number)3KC0434-2NE00-0AA0
Rated permanent current Iu (EF001389)160.0
● at AC / at 50/60 Hz / rated value415 V
● at AC-21 / at 500 V / rated value160 A
● at AC-21 / at 690 V / rated value160 A
Ambient temperature / during operation
Degree of protection (NEMA) (EF011959)Other
Suitable for floor mounting (EF007243)FALSE
Version as reversing switch (EF009408)-
WEEE (2012/19/EU) Take-Back ObligationYes
● protection class IP / on the frontIP20
Operating current / at AC / rated value160 A
● at 415 V / by gG fuse / rated value100 kA
● at AC-21 A / at 415 V / rated value160 A
● at AC-22 A / at 415 V / rated value160 A
● at AC-22 A / at 500 V / rated value160 A
● at AC-22 A / at 690 V / rated value160 A
● at AC-23 A / at 415 V / rated value160 A
● at AC-23 A / at 500 V / rated value160 A
● at AC-23 A / at 690 V / rated value125 A
● at AC-31 B / at 415 V / rated value160 A
● at AC-32 B / at 415 V / rated value160 A
● at AC-33 B / at 415 V / rated value160 A
● at AC-35 B / at 400 V / rated value160 A
let-through current / with closed switch
● at AC-33 iB / at 415 V / rated value160 A
Type of the driving mechanism / motor driveNo
● Reference code / acc. to DIN EN 81346-2Q
● reference code / acc. to DIN EN 61346-2Q
Position / of the switch operating mechanismin center
Type of connectable conductor cross-sections
Max. rated operation voltage Ue AC (EF007355)415
Suitable for front mounting 4-hole (EF007247)false
Suitable for front mounting centre (EF007248)false
Suitable for intermediate mounting (EF007264)true
Number of CO contacts / for auxiliary contacts8
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
● finely stranded / with core end processing1x (2.5 ... 70 mm²)
Rated operation power at AC-3, 400 V (EF001364)-
Degree of protection (IP), front side (EF003118)IP20
Rated operation power at AC-23, 400 V (EF007027)90.0
● of the fuse / at 415 V / maximum permissible223 005 A²·s
● of the fuse / at 500 V / maximum permissible223 005 A²·s
Rated short-time withstand current lcw (EF007050)4.0
Version as emergency stop installation (EF006959)true
Version as maintenance-/service switch (EF006986)true
Operating current / of upstream fuse / rated value160 A
Rated permanent current at AC-21, 400 V (EF009165)160
Rated permanent current at AC-23, 400 V (EF011777)-
● of the aM fuse / at 690 V / maximum permissible235 000 A²·s
● of the gG fuse / at 690 V / maximum permissible226 005 A²·s
Conditioned rated short-circuit current Iq (EF001444)-
● at AC-23 A / at 400 V / at 50/60 Hz / rated value90 kW
● at AC-23 A / at 690 V / at 50/60 Hz / rated value110 kW
● with conventional rated thermal current / per pole7 W
Suitable for distribution board installation (EF007262)true
Number of connected CO contacts / for auxiliary contacts0
Number of connected NC contacts / for auxiliary contacts0
Number of connected NO contacts / for auxiliary contacts0
Type of electrical connection of main circuit (EF006819)Frame clamp
● with conventional rated thermal current / per device28 W
● Mounting type / front mounting with 4-hole attachmentNo
● Mounting type / front mounting with central attachmentNo
● Type of electrical connection / for main current circuitbox terminal
● at 500 V / by gG fuse / acc. to IEC 60947-3 / rated value100 kA
● at 690 V / by gG fuse / acc. to IEC 60947-3 / rated value65 kA
Number of auxiliary contacts as change-over contact (EF003531)8
● at 415 V / by gG fuse / acc. to IEC 60947-6-1 / rated value100 kA
Number of auxiliary contacts as normally open contact (EF001376)0
Conditional short-circuit current / with line-side fuse protection
Number of auxiliary contacts as normally closed contact (EF001377)0
let-through current / of the fuse / at 500 V / maximum permissible18 005 A
● for combination switch + fuse / at 500 V / maximum permissible17 900 A
Type of connectable conductor cross-sections / for copper conductor
Type of connectable conductor cross-sections / with flexible busbar3x (0.8x14 mm²)
Short-circuit current making capacity (Icm) / for switch disconnector
let-through current / of the aM fuse / at 690 V / maximum permissible16 700 A
let-through current / of the gG fuse / at 690 V / maximum permissible16 005 A
● at 690 V / for combination switch + aM fuse / maximum permissible17 600 A
● at 690 V / for combination switch + gG fuse / maximum permissible18 700 A
Compliance with the substance restrictions according to RoHS directiveSince: 21.01.2016
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
● with closed switch / for combination switch + fuse / at 415 V / maximum135 600 A²·s
● with closed switch / for combination switch + fuse / at 500 V / maximum135 600 A²·s
● Protection class IP / with closed switch / with cover or cable lug coverIP20
● for rated value of the current / at AC / in hot operating state / per pole7 W
● with closed switch / at 690 V / for combination switch + aM fuse / maximum201 200 A²·s
● with closed switch / at 690 V / for combination switch + gG fuse / maximum178 300 A²·s
General Product ApprovalDeclaration of ConformityShipping ApprovalMiscellaneousGeneral Product Approval
● at AC 690 V / without fuse link / acc. to IEC 60947-3 / rated value / minimum12 kA
Mechanical service life (switching cycles) / for function sequence O-I-O / typical15 000
● at AC 415 V / without fuse link / acc. to IEC 60947-6-1 / rated value / minimum17 kA
Display version / for switch position indicator door-coupling rotary operating mechanismI ON- O OFF- II ON

Product Description

TRANSF SWITCH. MANUAL MTSE, TAM. 2, 160A, 4 POLES FRONT ACCONAMIENTO BASE UNIT WITHOUT HANDLE BOX TERMINALS. Cancelations and returns limited. Consult conditions.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top