| Parameter | Value |
|---|---|
| Value | |
| EAN | 4001869537436 |
| UPC | Not available |
| ETIM | 5 |
| Depth | 84.5 mm |
| Width | 255.6 mm |
| Height | 126 mm |
| UNSPSC | 15 |
| eClass | 6 |
| I2t value | |
| ● solid | 1x (2.5 ... 16 mm²) |
| Group Code | P360 |
| net weight | 2 100 g |
| Price Group | 12S |
| ● maximum | 70 °C |
| ● minimum | -25 °C |
| Metal Factor | None |
| ● stranded | 1x (10 ... 70 mm²) |
| Mounting type | Screw fixing and standard rail mounting 35 mm |
| Product Group | 5380 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| Commodity Code | 85365080 |
| Power loss [W] | |
| Product family | Basic Devices |
| Type of device | fixed mounting |
| Net Weight (kg) | 2,238 Kg |
| Operating power | |
| number of poles | 3 |
| ● Main switch | Yes |
| ● motor drive | No |
| ● rated value | 1 000 V |
| Design of handle | without |
| Country of origin | China |
| Operating current | |
| Operating voltage | |
| mounting position | any |
| ● safety switch | Yes |
| Continuous current | |
| Insulation voltage | |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| product brand name | SENTRON |
| Degree of pollution | 3 |
| Packaging Dimension | 126,00 x 256,00 x 85,00 |
| Product Description | SENTRON, 3KC transfer switching equipment, manually operated, MTSE, size: 2, 3-pole, Iu: 125 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 125 A, Ie at AC-23 A at 690 V: 125 A, screw and standard mounting rail installation 35 mm, Front operating mechanism, centered, without handle, box terminal |
| Product designation | 3KC transfer switching equipment |
| Protection class IP | IP20 |
| Suitability for use | |
| ● Voltage trigger | No |
| overvoltage category | III |
| Design of the product | manually operated |
| ● for copper busbar | 1x (3x14 mm²) |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● switch disconnector | Yes |
| General Product Approval | Declaration of Conformity |
| Interlockable (EF006281) | false |
| ● EMERGENCY OFF switch | Yes |
| Export Control Regulations | AL : N / ECCN : N |
| Number of poles (EF001391) | 3 |
| Product feature / interlock | No |
| Size of switch disconnector | 2 |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| ● at 40 °C / rated value | 125 A |
| ● at 45 °C / rated value | 125 A |
| ● at 50 °C / rated value | 125 A |
| ● at 55 °C / rated value | 125 A |
| ● at 60 °C / rated value | 125 A |
| ● at 65 °C / rated value | 125 A |
| ● at 70 °C / rated value | 125 A |
| Package size unit of measure | MM |
| Product extension / optional | |
| Number of switches (EF005586) | - |
| Type of the driving mechanism | Front operating mechanism |
| ● maintenance/repair switch | Yes |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Product Dimensions (W x L x H) | Not available |
| Motor drive optional (EF007386) | false |
| Operating current / rated value | 125 A |
| Colour control element (EF007167) | - |
| Design of the operating mechanism | Without handle |
| Motor drive integrated (EF006697) | false |
| Version as main switch (EF006981) | true |
| ● mounting type / rail mounting | Yes |
| Rated operating voltage (EF001435) | - |
| Type of control element (EF006976) | None |
| Switching power at 400 V (EF009166) | - |
| Version as safety switch (EF006985) | true |
| Voltage release optional (EF007491) | false |
| Ambient temperature / during storage | |
| Product extension / Auxiliary switch | Yes |
| Article Number (Market Facing Number) | 3KC0332-2NE00-0AA0 |
| Rated permanent current Iu (EF001389) | 125.0 |
| ● at AC / at 50/60 Hz / rated value | 415 V |
| ● at AC-21 / at 500 V / rated value | 125 A |
| ● at AC-21 / at 690 V / rated value | 125 A |
| Ambient temperature / during operation | |
| Degree of protection (NEMA) (EF011959) | Other |
| Suitable for floor mounting (EF007243) | FALSE |
| Version as reversing switch (EF009408) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● protection class IP / on the front | IP20 |
| Operating current / at AC / rated value | 125 A |
| ● at 415 V / by gG fuse / rated value | 100 kA |
| ● at AC-21 A / at 415 V / rated value | 125 A |
| ● at AC-22 A / at 415 V / rated value | 125 A |
| ● at AC-22 A / at 500 V / rated value | 125 A |
| ● at AC-22 A / at 690 V / rated value | 125 A |
| ● at AC-23 A / at 415 V / rated value | 125 A |
| ● at AC-23 A / at 500 V / rated value | 125 A |
| ● at AC-23 A / at 690 V / rated value | 125 A |
| ● at AC-31 B / at 415 V / rated value | 125 A |
| ● at AC-32 B / at 415 V / rated value | 125 A |
| ● at AC-33 B / at 415 V / rated value | 125 A |
| ● at AC-35 B / at 400 V / rated value | 125 A |
| let-through current / with closed switch | |
| ● at AC-33 iB / at 415 V / rated value | 125 A |
| Type of the driving mechanism / motor drive | No |
| ● Reference code / acc. to DIN EN 81346-2 | Q |
| ● reference code / acc. to DIN EN 61346-2 | Q |
| Position / of the switch operating mechanism | in center |
| Type of connectable conductor cross-sections | |
| Max. rated operation voltage Ue AC (EF007355) | 415 |
| Suitable for front mounting 4-hole (EF007247) | false |
| Suitable for front mounting centre (EF007248) | false |
| Suitable for intermediate mounting (EF007264) | true |
| Number of CO contacts / for auxiliary contacts | 8 |
| Number of NC contacts / for auxiliary contacts | 0 |
| Number of NO contacts / for auxiliary contacts | 0 |
| ● finely stranded / with core end processing | 1x (2.5 ... 70 mm²) |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Degree of protection (IP), front side (EF003118) | IP20 |
| Rated operation power at AC-23, 400 V (EF007027) | 55.0 |
| ● of the fuse / at 415 V / maximum permissible | 223 005 A²·s |
| ● of the fuse / at 500 V / maximum permissible | 223 005 A²·s |
| Rated short-time withstand current lcw (EF007050) | 4.0 |
| Version as emergency stop installation (EF006959) | true |
| Version as maintenance-/service switch (EF006986) | true |
| Operating current / of upstream fuse / rated value | 160 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 125 |
| Rated permanent current at AC-23, 400 V (EF011777) | - |
| ● of the aM fuse / at 690 V / maximum permissible | 235 000 A²·s |
| ● of the gG fuse / at 690 V / maximum permissible | 226 005 A²·s |
| Conditioned rated short-circuit current Iq (EF001444) | - |
| ● at AC-23 A / at 400 V / at 50/60 Hz / rated value | 55 kW |
| ● at AC-23 A / at 690 V / at 50/60 Hz / rated value | 110 kW |
| ● with conventional rated thermal current / per pole | 4.5 W |
| Suitable for distribution board installation (EF007262) | true |
| Number of connected CO contacts / for auxiliary contacts | 0 |
| Number of connected NC contacts / for auxiliary contacts | 0 |
| Number of connected NO contacts / for auxiliary contacts | 0 |
| Type of electrical connection of main circuit (EF006819) | Frame clamp |
| ● with conventional rated thermal current / per device | 13.5 W |
| ● Mounting type / front mounting with 4-hole attachment | No |
| ● Mounting type / front mounting with central attachment | No |
| ● Type of electrical connection / for main current circuit | box terminal |
| ● at 500 V / by gG fuse / acc. to IEC 60947-3 / rated value | 100 kA |
| ● at 690 V / by gG fuse / acc. to IEC 60947-3 / rated value | 65 kA |
| Number of auxiliary contacts as change-over contact (EF003531) | 8 |
| ● at 415 V / by gG fuse / acc. to IEC 60947-6-1 / rated value | 100 kA |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Conditional short-circuit current / with line-side fuse protection | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| let-through current / of the fuse / at 500 V / maximum permissible | 18 005 A |
| ● for combination switch + fuse / at 500 V / maximum permissible | 17 900 A |
| Type of connectable conductor cross-sections / for copper conductor | |
| Type of connectable conductor cross-sections / with flexible busbar | 3x (0.8x14 mm²) |
| Short-circuit current making capacity (Icm) / for switch disconnector | |
| let-through current / of the aM fuse / at 690 V / maximum permissible | 16 700 A |
| let-through current / of the gG fuse / at 690 V / maximum permissible | 16 005 A |
| ● at 690 V / for combination switch + aM fuse / maximum permissible | 17 600 A |
| ● at 690 V / for combination switch + gG fuse / maximum permissible | 18 700 A |
| Compliance with the substance restrictions according to RoHS directive | Since: 21.01.2016 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| ● with closed switch / for combination switch + fuse / at 415 V / maximum | 135 600 A²·s |
| ● with closed switch / for combination switch + fuse / at 500 V / maximum | 135 600 A²·s |
| ● Protection class IP / with closed switch / with cover or cable lug cover | IP20 |
| ● for rated value of the current / at AC / in hot operating state / per pole | 4.5 W |
| ● with closed switch / at 690 V / for combination switch + aM fuse / maximum | 201 200 A²·s |
| ● with closed switch / at 690 V / for combination switch + gG fuse / maximum | 178 300 A²·s |
| General Product ApprovalDeclaration of ConformityShipping ApprovalMiscellaneous | General Product Approval |
| ● at AC 690 V / without fuse link / acc. to IEC 60947-3 / rated value / minimum | 12 kA |
| Mechanical service life (switching cycles) / for function sequence O-I-O / typical | 15 000 |
| ● at AC 415 V / without fuse link / acc. to IEC 60947-6-1 / rated value / minimum | 17 kA |
| Display version / for switch position indicator door-coupling rotary operating mechanism | I ON- O OFF- II ON |
Technical specifications and performance data
Installation and operation guide