| Parameter | Value |
|---|---|
| Customs Tariff Number: | 85044090 |
| Minimum Order Quantity: | 1 piece |
| Ramp Time: (Dimensions) | During Start 1 ... 10 second [unit of time]During Stop 0 ... 20 second [unit of time] |
| RoHS Status: (Technical) | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| Communication: (Dimensions) | FiledBusPlug(Optional) |
| Terminal Type: (Dimensions) | Screw Terminals |
| Run Signal Relay: (Dimensions) | Yes |
| ETIM 4: (Container Information) | EC002572 - Electronic motor control and protection device |
| ETIM 5: (Container Information) | EC002572 - Electronic motor control and protection device |
| Product Main Type: (Dimensions) | PSR30 |
| Tightening Torque: (Dimensions) | Main Circuit 2.3 N·mSupply Circuit 0.6 N·mControl Circuit 0.6 N·m |
| UNSPSC: (Container Information) | 39121521 |
| Fault Signal Relay: (Dimensions) | No |
| E-nummer: (Container Information) | 3302048 |
| Overload Protection: (Dimensions) | Recommended MS132 25 … 32 |
| Rated Frequency (f): (Dimensions) | Main Circuit 50/60 HzControl Supply 50/60 Hz |
| RoHS Information: (Environmental) | 1SFC132031D0202 |
| By-pass Signal Relay: (Dimensions) | Yes |
| Degree of Protection: (Dimensions) | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Overload Signal Relay: (Dimensions) | No |
| Ambient Air Temperature: (Technical) | Storage -40 ... +70 °COperation -25 ... +60 °C |
| Current Limit Function: (Dimensions) | No |
| Instructions and Manuals: (Ordering) | 1SFC132031M0001 |
| Product Net Width: (Popular Downloads) | 45.000 mm |
| Product Net Height: (Popular Downloads) | 160.000 mm |
| Product Net Weight: (Popular Downloads) | 0.65 kg |
| Rated Operational Voltage: (Dimensions) | Main Circuit 208 ... 600 V AC |
| Service Factor Percentage: (Dimensions) | 100 % |
| Instructions and Manuals: (Environmental) | 1SFC132031M0001 |
| Environmental Information: (Environmental) | 1SFC132038D0201 |
| Initial Voltage During Start: (Dimensions) | 40 ... 70 % |
| Integrated Electronic Overload: (Dimensions) | No |
| Step Down Voltage Special Ramp: (Dimensions) | 100 ... 60 % |
| Data Sheet, Technical Information: (Ordering) | 1SFC132005C0201 |
| Connecting Capacity Main Circuit: (Dimensions) | Rigid 1/2x2.5 ... 10 mm² |
| Adjustable Rated Motor Current Ie: (Dimensions) | No % |
| Declaration of Conformity - CE: (Environmental) | 1SFA1-90 |
| Product Net Depth / Length: (Popular Downloads) | 128.000 mm |
| Rated Control Supply Voltage (Us): (Dimensions) | 100 ... 240 V AC |
| Signal indication running R (LED): (Dimensions) | Green |
| Connecting Capacity Supply Circuit: (Dimensions) | Rigid 1x0.75 ... 2.5 mm²Rigid 2x0.75 ... 1.5 mm² |
| Rated Control Circuit Voltage (Uc): (Dimensions) | 50 Hz / 60 Hz 100 ... 240 V AC |
| Switch for Inside Delta Connection: (Dimensions) | No |
| Connecting Capacity Control Circuit: (Dimensions) | Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm² |
| Object Classification Code: (Container Information) | Q |
| Signal indication ramping up/down (LED): (Dimensions) | Green |
| Signal indication completed start ramp (LED): (Dimensions) | Green |
| Starting Capacity at Maximum Rated Current Ie: (Dimensions) | 4xIe for 6s |
| Rated Operational Power - In-Line Connection (Pe): (Dimensions) | (230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kW |
| Signal indication ready to start/standby ON (LED): (Dimensions) | Green |
| Rated Operational Current - In-Line Connection (Ie): (Dimensions) | 30 A |
| Package Level 1 EAN: (Certificates and Declarations (Document Number)) | 7320500338308 |
| Package Level 1 Units: (Certificates and Declarations (Document Number)) | 1 piece |
| Package Level 1 Width: (Certificates and Declarations (Document Number)) | 51 mm |
| Package Level 2 Units: (Certificates and Declarations (Document Number)) | 1 piece |
| Package Level 1 Height: (Certificates and Declarations (Document Number)) | 137 mm |
| Package Level 1 Gross Weight: (Certificates and Declarations (Document Number)) | 0.75 kg |
| Package Level 1 Depth / Length: (Certificates and Declarations (Document Number)) | 178 mm |
| Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time: (Dimensions) | 10 |
Technical specifications and performance data