Service time: Monday to Friday 9:00-18:00
1SAZ421201R1002 - 1SAZ421201R1002 ABB TA200DU-110 Thermal Overload Relay
In Stock Hot Product

1SAZ421201R1002

1SAZ421201R1002 ABB TA200DU-110 Thermal Overload Relay

$0.00USD
3224 in stock
Key Specifications
:Auxiliary Circuit 500 V AC
ETIM 4:EC000106 - Thermal overload relay
ETIM 5:EC000106 - Thermal overload relay
ETIM 6:EC000106 - Thermal overload relay
Supplier Information
ABB
ABB
Products: 44170
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Auxiliary Circuit 500 V AC
ETIM 4EC000106 - Thermal overload relay
ETIM 5EC000106 - Thermal overload relay
ETIM 6EC000106 - Thermal overload relay
ETIM 7EC000106 - Thermal overload relay
ETIM 8EC000106 - Thermal overload relay
UNSPSC39122330
eClassV11.0 : 27371501
StandardsIEC/EN 60947-1
Power Lossat Rated Operating Conditions per Pole 2.5 ... 4.7 W
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Feature NameFeature Value
Suitable ForA145
Setting Range80 ... 110 A
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate1SAA941000-0201
CB Certificate1SAA941004-2003
GL Certificate1SAA941000-0304
LR Certificate1SAA941000-0504
UL CertificateE48139-19910930
WEEE B2C / B2BBusiness To Business
ABS Certificate1SAA941000-0102
CQC CertificateCQC2016010309922936
DNV Certificate1SAA941000-0304
EAC Certificate1SAA941002-2702
Number of Poles3
Pollution Degree3
RMRS Certificate1SAA941000-0704
RoHS Information1SAD938518-0043
Dimension Diagram1SAZ400401F0001
E-Number (Sweden)3228702
Mounting Position1 ... 6
Product Net Width104 mm
Tightening TorqueAuxiliary Circuit 1 ... 1.3 N·m
DNV GL Certificate1SAA941000-0304
E-Number (Finland)3709358
Product Net Height151 mm
Product Net Weight0.76 kg
Package Level 1 EAN4013614286025
Package Level 2 EAN4013614494246
Rated Frequency (f)Auxiliary Circuit 50 Hz
Degree of ProtectionHousing IP20
Contact Rating UL/CSA(NC:) B600
Customs Tariff Number85364900
Package Level 1 Units1 piece
Package Level 1 Width165 mm
Package Level 2 Units4 piece
Package Level 2 Width280 mm
Wire Stripping LengthAuxiliary Circuit 9 mm
Minimum Order Quantity1 piece
Package Level 1 Height133 mm
Package Level 2 Height210 mm
Ambient Air TemperatureOperation -25 ... +55 °C
CAD Dimensional Drawing2CDC001079B0201
End of Life Instructions1SAC200335H0001
Instructions and Manuals2CDC106028M6802
Recommended Screw DriverAuxiliary Circuit Pozidriv 1
Release class (EF006668)CLASS 10 A
Tightening Torque UL/CSAAuxiliary Circuit 12 in·lb
Environmental Information1SAC200056H0009
Number of Protected Poles3
Rated Operational VoltageAuxiliary Circuit 440 V DC
Mounting method (EF000003)Direct attachment
Object Classification CodeF
Product Net Depth / Length126 mm
Package Level 1 Gross Weight1.01 kg
Package Level 2 Gross Weight8.786 kg
Rated Insulation Voltage (Ui)690 V
Declaration of Conformity - CE1SAD101100-3509
Package Level 1 Depth / Length151 mm
Package Level 2 Depth / Length395 mm
Rated Operational Current (Ie)110 A
Declaration of Conformity - CCC2020980304001321
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Reset function input (EF011940)No
Connecting Capacity Main CircuitHole Diameter > 10 mm²
Declaration of Conformity - UKCA1SAD201100-3509
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals (Part 2)1SAC200017M0002
Time-Current Characteristic Curve1SAZ400502F0002
IDEA Granular Category Code (IGCC)5366 >> Thermal overload relay
Adjustable current range (EF008211)110 A
Reset function automatic (EF011941)Yes
Toxic Substances Control Act - TSCA2CMT2023-006525
Ambient Air Temperature CompensationYes
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.25 A
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Reset function push-button (EF011942)Yes
Maximum Operating Altitude Permissible2000 m
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Connecting Capacity Main Circuit UL/CSAFlexible 1x 4-0000 AWG
Max. rated operation voltage Ue (EF007357)690 V
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 12g
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 5 A
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-14 AWG
Type of electrical connection of main circuit (EF006819)Screw connection
Number of auxiliary contacts as change-over contact (EF003531)1
Number of auxiliary contacts as normally open contact (EF001376)1
Number of auxiliary contacts as normally closed contact (EF001377)1

Product Description

TA200DU110 THERMAL RELAY 80-110A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top