Service time: Monday to Friday 9:00-18:00
1SAM360200R1011 - 1SAM360200R1011 ABB MO132-16B Magnetic only motor guard
In Stock Hot Product

1SAM360200R1011

1SAM360200R1011 ABB MO132-16B Magnetic only motor guard

$0.00USD
4514 in stock
Key Specifications
:1SAM300507F0003
ETIM 5:EC000074 - Motor protective circuit-breaker
ETIM 6:EC000074 - Motor protection circuit-breaker
ETIM 7:EC000074 - Motor protection circuit-breaker
Supplier Information
ABB
ABB
Products: 44170
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1SAM300507F0003
ETIM 5EC000074 - Motor protective circuit-breaker
ETIM 6EC000074 - Motor protection circuit-breaker
ETIM 7EC000074 - Motor protection circuit-breaker
ETIM 8EC000074 - Motor protection circuit-breaker
UNSPSC39121521
eClassV11.0 : 27370401
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used
StandardsIEC 60077-1 (applicable parts)
Power Lossat Rated Operating Conditions per Pole 1.9 W
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Actuator TypeRotary Handle
Setting RangeNone
Terminal TypeScrew Terminals
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate1SAA963002-2002
UL CertificateE137861-20090225
WEEE B2C / B2BBusiness To Business
CCC Certificate2020980307003526
CQC CertificateCQC2010010307387700
Number of Poles3
Pollution Degree3
RoHS Information1SAA963006-4502
Dimension Diagram1SAM300402F0002
Locked Rotor Amps(200 V AC) Three Phase 73.6 A
Mounting Position1 ... 6
Product Net Width45 mm
REACH Declaration1SAA963005-4502
Tightening TorqueMain Circuit 1.5 N·m
Product Net Height97.8 mm
Product Net Weight0.31 kg
I²t Characteristic1SAM300507F0001
Package Level 1 EAN4013614521584
Package Level 2 EAN4013614523151
Rated Frequency (f)Main Circuit 50 Hz
Degree of ProtectionHousing IP20
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Customs Tariff Number85362010
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 2 Unitscarton 30 piece
Package Level 2 Width280 mm
Wire Stripping LengthMain Circuit 10 mm
Minimum Order Quantity1 piece
Package Level 1 Height50 mm
Package Level 2 Height210 mm
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C
CAD Dimensional Drawing2CDC001079B0201
End of Life Instructions1SAC200332H0001
Full Load Amps Motor Use(200 V AC) Three Phase 11 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 3 Hp
Instructions and Manuals2CDC131034M6801
Recommended Screw DriverPozidriv 2
Resistance to Vibrations5g 3 ... 150 Hz
Tightening Torque UL/CSAMain Circuit 18 in·lb
General Use Rating UL/CSA(600 V AC) 16 A
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Operating Frequency (fsw)0 ... 400 Hz
Rated Operational VoltageMain Circuit 690 V AC
Object Classification CodeF
Product Net Depth / Length86.55 mm
Contact Position IndicationON / OFF / TRIP
Package Level 1 Gross Weight0.325 kg
Package Level 2 Gross Weight13.386 kg
Rated Insulation Voltage (Ui)690 V
Cut-off Current Characteristic1SAM300508F0001
Declaration of Conformity - CE1SAD101100-3407
Package Level 1 Depth / Length102 mm
Package Level 2 Depth / Length395 mm
Rated Operational Current (Ie)16 A
Declaration of Conformity - CCC2020980307003526
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm²
Declaration of Conformity - UKCA1SAD201100-3407
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Data Sheet, Technical Information1SBC100200C02__
Instructions and Manuals (Part 2)2CDC131060M0202
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 7.5 kW
Time-Current Characteristic Curve1SAM300515F0008
IDEA Granular Category Code (IGCC)4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 7.5 kW
Rated Operational Current AC-3 (Ie)16 A
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Toxic Substances Control Act - TSCA2CMT2023-006539
Ambient Air Temperature CompensationNo
Rated Operational Current AC-3e (Ie)16 A
Maximum Operating Altitude Permissible2000 m
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Conventional Free-air Thermal Current (Ith)Main Circuit 16 A
Shock and Vibration Withstand acc. to IEC 61373Category 1, Class B
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)200 A

Product Description

MO132-16B Manual Motor Starter Magnetic Only 16 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top