


| Parameter | Value |
|---|---|
| MCC | 12.1 A |
| RLA | 8.6 A |
| Region | Africa; Europe; Middle East |
| DLLP_CU | 4 |
| K limit | 647 |
| Version | A02 |
| Type Code | Optyma™ |
| Net weight | 100.00 Kg |
| Width [mm] | 1000 |
| Length [mm] | 700 |
| Refrigerant | R404A; R507 |
| Applications | LBP |
| Gross weight | 100.00 Kg |
| Model number | OP-LGHC108NTA02E |
| • Receiver | 8168181 |
| Segment usage | Low Back Pressure |
| • Condenser | 8174041 |
| Condenser type | G3 |
| Number of fans | 2 |
| • Compressor | 120F0011 |
| Electrical code | E |
| Compressor model | NTZ108-4 |
| Type designation | Condensing Units |
| Voltage 50Hz [V] | 400 |
| • Fan assembly | 8176045 |
| Receiver approval | CE |
| Total height [mm] | 555 |
| • Suction valve | 7968017 |
| Approval standards | CE - LVD |
| Fan blade size [mm] | 350 |
| No. of phases (fan) | 1 |
| • Discharge valve | 7968014 |
| • Crankcase heater | 7773107 |
| Fan current @ 50Hz [A] | 0.58 |
| Fan current @ 60Hz [A] | 0.83 |
| Voltage 50Hz [V] [Max] | 400 |
| Air flow @ 50Hz [m³/h] | 4600 |
| • Dual pressure switch | 060-539766 |
| • Receiver Description | 8L |
| • Condenser Description | H3 |
| Fan power supply [V/Ph/Hz] | 230/1/50 |
| No. of phases (compressor) | 3 |
| Sound power @ 50Hz [db(A)] | 83 |
| • Compressor Description | NTZ108-4 |
| • Compressor single pack | 120F0004 |
| Liquid line connection [in] | 1/2 |
| Suction connection size [in] | 7/8 |
| • Fan assembly Description | D350 230/1/50-60 |
| • Suction valve Description | V07 |
| • Discharge valve Description | V09 |
| Fan power consumption @ 50Hz [W] | 130 |
| Fan power consumption @ 60Hz [W] | 190 |
| • Crankcase heater Description | Belt type crankcase heater, 65 W, 230 V, CE mark, UL |
| Compressor power supply [V/Ph/Hz] | 400/3/50 |
| Fan voltage @ 50Hz (max) [V] [Max] | 230 |
| Fan voltage @ 50Hz (max) [V] [Min] | 230 |
| • Dual pressure switch Description | KP 17 WB |
| • Compressor single pack Description | NTZ108-4 |
Technical specifications and performance data
Installation and operation guide