| Parameter | Value |
|---|---|
| Oil | POE |
| RLA | 2.0 |
| Color | Black |
| Phase | One |
| Economizer | Not |
| Net weight | 8 Kg |
| Technology | Alternative |
| Description | DLE7.5CN |
| Engine type | CSIRRSCRRSIR |
| LRA HST [A] | 9.8 To |
| LRA LST [A] | 9.6 To |
| Applications | LBPMBP |
| Gross weight | 8.2 Kg |
| Model number | DLE7.5CN |
| Refrigerants | R290 |
| Amount of oil | 230 cm3 |
| Frequency [Hz] | Fifty |
| Oil charge [L] | 0.23 L |
| Use of segment | Refrigeration LTRefrigeration MT |
| Capacity control | Fixed speed |
| Packaging format | Industrial package |
| Type designation | Compressor |
| Units of packing | One hundred |
| Configuration code | Individual |
| Swept volume [cm3] | 7.48 cm3 |
| Voltage, 50 Hz [V] | 220 V |
| Type of motherboard | EU, small |
| N. º of phases (fan) | One |
| Technique of the brand | Reciprocating compressors, type |
| Capacity of capacitor B | 80 uF |
| LRA HST, alternative [A] | 9.8 To |
| Volume of free gas [cm3] | 1 cm3 |
| Run capacitor capacitance | 5 µF |
| Voltage, 50 Hz [V] [max.] | 240 V |
| Current connection HST [A] | 9.8 To |
| Current connection LST [A] | 15.2 |
| Ability of the capacitor To | 5 µF |
| Start capacitor capacitance | 80 µF |
| Merged Approval standard and | CCCCE en 60335-2-34 with Annex AA |
| N. º of phases (compressor) | One |
| Refrigerant charge [kg] [Max] | 0.15 kg |
| Rotation speed at 50 Hz [rpm] | 2900 rpm |
| Rotation speed at 60 Hz [rpm] | 0 rpm |
| Energy level of the application | Compressor energy-optimized |
| Material of the process connection | Copper |
| Material of the discharge connection | Copper |
| Low value of voltage range at 50hz [V] | 198 V |
| High value of voltage range at 50hz [V] | 254 V |
| Winding temperature, stable [°C] [Max] | 125 °C |
| High value of nominal voltage at 50 Hz [V] | 230 V |
| Low value of the rated voltage at 50 Hz [V] | 220 V |
| Low value of the voltage range at 60 Hz [V] | 0 V |
| High value of the voltage range at 60 Hz [V] | 0 V |
| Low value of the nominal voltage at 60 Hz [V] | 0 V |
| High value of the nominal voltage at 60 Hz [V] | 0 V |
| Temperature of the winding, the short-term [°C] [Max] | 135 °C |
| Resistance of the primary winding for compressors in single-phase [Ohm] | 10.9 Ohm |
| Auxiliary winding resistance (start winding) for single-phase compressors [Ohm] | 8.34 Ohm |
Technical specifications and performance data
Installation and operation guide