| Parameter | Value |
|---|---|
| EAN () | 5710104013268 |
| Type () | ECL Comfort 310 |
| Volume () | 4.859 Liter |
| Approval () | CE |
| Net weight () | 0.433 Kilogram |
| Description () | ECL COMFORT 310B/230 V |
| CE evaluated () | Yes |
| Display type () | LCD dot matrix |
| EEE category () | 5 small equipment (any external dimension50 cm) |
| Gross weight () | 0.618 Kilogram |
| DHW functions () | Anti-bacteria programAuto-tunningReturn temperature influence |
| Product group () | Electronic controllers |
| Communications () | ECL 485 Bus (non-galvanically isolated)M-BusModbus (galvanically isolated) |
| Number of pumps () | 5 |
| In scope of WEEE () | Yes |
| SCIP dossier no. () | ad51fccb-924b-4843-a9b7-7e3da2fef171 |
| Time switch type () | Week |
| Approval standard () | EMC-Directive: 2004/108/ECEmission: EN 61000-6-3:2007EN 60730Immunity: EN 61000-6-1:2007LVD directive 2006/95/EC |
| General functions () | Alarm functionsCirculation pump exerciseControl valve exerciseExternal override facilityFrost protectionHoliday programMaster - Slave networkMotor protectionRemote control connection |
| Application source () | By ECL application key |
| EU RoHS compliance () | Yes with exemptions |
| Grade of enclosure () | IP41 |
| UK RoHS compliance () | Out of scope |
| Digital inputs type () | 12 V pull-up possible |
| China RoHS compliance () | Out of scope |
| Power consumption [W] () | 5 W |
| Supply voltage [V] AC () | 230 V |
| Number of DHW circuits () | 2 |
| Number of Sensor inputs () | 10 pc |
| Number of relay outputs () | 6 |
| Sensor cable length [m] () | 200 m |
| EU RoHS exemption clause () | 6(c) |
| Number of digital inputs () | 4 |
| Sensor cable length [mm] () | 200 mm |
| Temperature sensors type () | Pt 1000, configurable input |
| Actuator output load [VA] () | 15 VA |
| SCIP dossier product name () | ECL Comfort 310 and 210 |
| Number of heating circuits () | 3 |
| Relay output ohmic load [A] () | 4 A |
| Relay output voltage [V] AC () | 230 V |
| Supply voltage [V] AC [max] () | 244 V |
| Supply voltage [V] AC [min] () | 207 V |
| Time switch power backup [h] () | 72 h |
| Ambient humidity [% RH] [Max] () | 65 % |
| Supply voltage frequency [Hz] () | 50 Hz |
| Ambient temperature [°C] [max] () | 55 °C |
| Ambient temperature [°C] [min] () | 0 °C |
| REACH Candidate List substances () | Lead (CAS no. 7439-92-1)Lead monoxide (PbO, CAS no. 1317-36-8)Diboron trioxide (B2O3, CAS no. 1303-86-2)Lead titanium trioxide (CAS no. 12060-00-3)6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol (CAS no. 119-47-1) |
| Relay output inductive load [A] () | 2 A |
| Storage temperature [°C] [Max] () | 70 °C |
| Storage temperature [°C] [Min] () | -40 °C |
| Number of comfort periods per day () | 3 |
| Number of DHW storage tank circuits () | 1 |
| Heat curve setting for heating circuit () | 6 pointsSlope |
| In scope of WEEE and contain batteries () | No |
| Number of 3-point motor control outputs () | 3 |
Technical specifications and performance data
Installation and operation guide