| Parameter | Value |
|---|---|
| EAN | 5702428107839 |
| Core | Solid core |
| Brand | ELIMINATOR |
| Approval | UL |
| Category | Art. 3, par. 3 |
| Net weight | 2.98 Kg |
| Fluid Group | II |
| Serviceable | No |
| Gross weight | 3.16 Kg |
| Product name | Hermetic filter drier |
| Product type | DCL |
| Refrigerants | R1234yfR1234zeR125R134aR22/R407CR23R290R32R404AR407AR407FR410AR422BR422DR438AR444BR448AR449AR449BR450AR452AR452BR454BR455AR507AR513AR600 |
| Body material | Steel |
| Product Group | Filter driers |
| Core Size code | 60 cu.in. |
| Net volume [l] | 0.827 L |
| Packing format | Multi pack |
| Flow Capacity KW | R134a: 34.8R290: 41.9R32: 53.0R404A: 24.5R407C: 35.7R410A: 36.2R507: 23.7 |
| Flow Capacity TR | R134a: 9.9R290: 11.9R32: 15.1R404A: 7.0R407C: 10.1R410A: 10.3R507: 6.8 |
| Shell volume [l] | 1.34 L |
| Type designation | DCL 604S |
| Acid capacity [g] | 12.46 g |
| Specification key | DCL 604S |
| Acid capacity [oz] | 0.44 oz |
| Connection material | Steel Cu-plated |
| Net volume [foz US] | 27.96 oz |
| Product description | Liquid line filter drier |
| Product family name | DCL |
| Inlet connection type | SOLDER, ODF |
| Shell volume [foz US] | 45.44 oz |
| UL approval file name | SA6398 |
| Outlet connection type | SOLDER, ODF |
| Solid core volume [cm3] | 517 cm3 |
| Solid core volume [in3] | 31.54 in3 |
| System line application | Liquid line |
| Flow direction indicator | Label printed 1-way arrow |
| Solid core surface [cm2] | 339 cm2 |
| Solid core surface [in2] | 52.58 in2 |
| Max. Working Pressure [bar] | 46 bar |
| Quantity per packing format | 12 pc |
| Inlet 1 connection size [in] | 1/2 in |
| Max. Working Pressure [psig] | 667 psig |
| Outlet 1 connection size [in] | 1/2 in |
| Temperature range [°C] [Max] | 70 °C |
| Temperature range [°C] [Min] | -40 °C |
| Temperature range [°F] [Max] | 160 °F |
| Temperature range [°F] [Min] | -40 °F |
| Activated alum/Molec sieve [%] | 20% / 80% |
| LiqCap Cond (ARI 710-2009)[SI] | Delta p=0.07bartliq= 30°Ctvap=-15°C |
| LiqCapCond (ARI 710-2009)[IMP] | Delta p=1psitliq= 86°Ftvap=5°F |
| Drying Cap[Drops of Water]24°C | R134a: 1777R290: --R32: 1495R404A: 1851R407C: 1725R410A: 1608R507: 1938 |
| Drying Cap[Drops of Water]52°C | R134a: 1627R290: --R32: 1376R404A: 1753R407C: 1590R410A: 1431R507: 1744 |
Technical specifications and performance data